The EM101 is a small electromagnetic low-flow flowmeter with

chemically-resistant plastic wetted parts and platinum electrodes

suitable for use with a variety of chemicals. Capable of measur-

ing pulsating flows from diaphragm-type metering pumps, it is

designed primarily for electrically-conductive chemical injection

applications. The 1/4” and 3/8” sizes monitor maximum flows

of 1 and 3 gallons per minute (or 4 and 11 L/min), respectively.

Barb or NPT fittings are available, and must be designated at

time of order.

The EM101 is 115 Vac, 60 Hz powered and includes a rate and

total display as well as a variety of outputs. For continuous trans-

mission of a flow signal, there is a 4-20 mA output, a 0-5 volt signal,

and a frequency signal proportional to flow. In addition, there are

relay alarm outputs for user-set low and high flow levels.

GENERAL INFORMATION

FEATURES

Backlit LCD display

(16 characters x 2 lines)

Captive plastic cover screw (4)

(mounting screws inside)

Display

Flow

Meter

Polycarbonate housing

Power cord
Connector (2)

for optional output cables

Connector (2)

for sensor cables

6 ft. control cables (2)

out to display

10-24 grounding screws

(on bottom of meter)

Removable bracket

for mounting

PVDF plastic fittings (2)

Male NPT or barb

(must be designated at time of order)

Fusion coated

aluminum housing

Keypad switches, tactile

SPECIFICATIONS*

Fusion coated aluminum

Platinum

Viton™ (EPDM optional)

Polycarbonate

Gal/Minute, Liters/Second, Gal/Hour

Gallons, Liters

115 Vac, 60 Hz

+/-1% of reading,

plus .005 gpm (0.02 lpm)

185˚ F (85˚ C)

150 psi (@ 75˚ F)

>20 microSiemens/cm

• 4-20 mA, 0-5 Volts, both isolated

• Frequency to 9999 pulses per gallon, isolated (10 mA, 30 Vdc)

• High alarm, low alarm relay, isolated (100 mA, 110 Vac/Vdc)

Materials Meter housing

Electrodes

O-Ring

Display housing

Rate Display Units

Total Display Units

Power

Accuracy

Max Fluid Temperature

Maximum Pressure

Minimum Conductivity

Outputs

FLOW RANGE

SIZE

LOW FLOW CUTOFF

MINIMUM FLOW for spec accuracy

MAXIMUM FLOW

-025
-038

L/MIN

GAL/MIN

GAL/hR

L/MIN

GAL/MIN

GAL/hR

L/MIN

GAL/MIN

GAL/hR

.04

.01

.60

.26

.07

4.2

3.8

1

60

.11

.03

1.80

.76

0.2

12

11

3

180

*Specifications subject to change • Please consult our website for current data (www.seametrics.com).