TABLE 2: PIPE WALL THICKNESS

PIPE SIZES

2"

2-1/2"

3"

4"

5"

6"

8" 10" 12" 16" 24" 30" 36"

0.109

0.120 0.120 0.120 0.134 0.134 0.148 0.165 0.180 — — — —

0.154

0.203 0.216 0.237 0.258 0.280 0.322 0.365 0.406 0.500 0.687 — 0.750

0.218

0.276 0.300 0.337 0.375 0.432 0.500 0.593 0.687 0.843 1.218 — —

0.083

0.095 0.109 0.134 0.160 0.192 0.271 — — — — — —

0.070

0.080 0.090 0.100 0.125 0.140 0.200 — — — — — —

0.157

0.188 0.219 0.250 0.250 0.250 0.313 — — — — — —

— — 0.280 0.290 —

0.310 0.330 0.350 0.370 0.400 — — —

IPS Steel

Schedule(10S)

IPS Schedule (40)

IPS Schedule (80)

Copper Tubing

(Type K)

Copper Tubing

(Type L)

Copper Pipe

Class 52 Duct. Iron

TABLE 1: DIMENSION "C"

NOMINAL PIPE SIZE

2”

2.5”

3”

4”

5”

6”

8”

10”

12”

16”

24”

30”

36”

10.20

10.12

10.03

9.86

9.69

9.52

9.18

8.84

8.50

7.82

15.20

15.12

15.03

14.86

14.69

14.52

14.18

13.84 13.50

12.82 11.46 10.44

10.42

17.24

17.14

17.04

16.84

16.74

16.54

16.14

15.84 15.54

14.84

-

-

-

20.89

20.69

20.49

20.19

19.89 19.49

18.79 17.49 16.49 15.39

MX101

MX201

MX115

MX215

INSTALLATION

AR

CH

IVE

D

(Includes Dates Before 5/05)

Advertising