Badger Meter ORION Fixed Network (SE) User Manual

Page 3

Advertising
background image

Installation Data

Page 3

February 2014

ENDPOINT INSTALLATION REQUIREMENTS

Endpoints should be installed after gateways are installed to allow for full system testing at the time of endpoint deployment.
• Each installation crew should have access to the handheld test equipment to confirm deployment at each service location.
• Endpoints should be verified to be transmitting before the installer leaves the meter. Activation can be accomplished by

either running water through the meter or by starting it with the handheld.

• All endpoints should be installed in a location confirmed by the handheld test equipment to support two-way

communications to and from the gateway at the time of endpoint installation.

Pit Installations

All endpoints installed in a pit application must be installed through a non-metal lid.

All pit endpoints should be mounted at or above grade and not covered by grass, dirt, landscaping, etc., for optimal

RF propagation and to minimize the chance for flooding to cover the endpoint antenna assembly.

Indoor/Remote Installations

The endpoint normally should be installed as high as possible (in the floor joist) and as close to the outside wall as

possible. Several locations might need to be tested to determine the optimum location for RF propagation. In some

situations, the endpoint may need to be mounted on an outside wall.

Vault Installations

Solid metal vault lids may require the endpoint be brought out of the vault and installed in a small box next to

the vault.

NOTE:

N

Utilities installing endpoints in a mobile application prior to transitioning to a fixed network should take into

consideration where they install the endpoints. Badger Meter can prepare an RF propagation study to map out future

gateway locations. This allows the installer to make endpoint installation decisions based on the location of future

gateway deployments.

RELATED BADGER METER DOCUMENTS

To access all Badger Meter ORION Fixed Network installation documents, go to

www.badgermeter.com

.