Badger Meter M-Series M2000 User Manual

Installation & operation manual, M-series® m2000

Advertising
background image

M-Series® M2000

Store/Restore Feature

Installation & Operation Manual

IOM-194-01-EN (August 2012)

53400-194 Rev. 1

IMPORTANT

The Store/Restore feature requires firmware version 1.11 or

later. Reference Badger Meter P/N 67354-003 to obtain a

firmware upgrade kit.

DESCRIPTION

The Store/Restore feature is intended to save installation

costs and reduce installation time. This feature is also

intended to protect meter configuration and assure the

operator that the meter is properly configured. Over time

and handling of the meter, the meter configuration could

change. The Store/Restore feature allows the meter to be

quickly set to the operator’s original configuration.

PERFORMANCE

The Store/Restore feature provides the ability to save meter

configuration to a memory token. The memory token can

be placed into alternate meters so that each meter in the

system has the same configuration. The memory token can

also be stored in a safe place and later used to restore meter

configuration if the configuration of the meter is in question.

The operator has the option to select which groups of

configuration parameters are stored to the memory token,

providing additional flexibility for system installation.

OPERATION

The means to enable and configure the Store/Restore

feature are found under the Advanced menu of the menu

manager located in the Token Copy submenu. The menu

items of Token Copy are:
• Configuration

Token Properties

Parameter Selection

• Store to Token

• Restore to Token
The Configuration submenu allows the operator to configure

token properties and select the groups of parameters that

are to be stored to the token. Token properties and the

parameter selection configurations should be configured

first, prior to copying meter information to the

memory token.

Token properties allow the token to be configured in a

way that the behavior of the token can be defined. Such

properties include:
• Write Protect – Protects the token from being overwritten

• Power on Load – Requests the meter to load the contents

of the token into the meter at power on.

• One Time Load – Requests the meter to erase the token

after the contents of the token have been stored to the

meter.

Write protect cannot be undone by the operator. Caution

should be used when configuring the token for write-

protect mode.
The chart below lists the categories of parameters that can

be individually selected for storing to the memory token.

Parameter Categories

Calibration

Pipe diameter
Detector factor
Detector offset

Communication port A/B

Interface (for port A only)
Node address
Baud rate
Parity
Date bits
Stop bits
Extended node address (for

port B, Profibus DP only)

Security

Admin pin
Service pin
User pin

User

All other meter parameters

including measurement and

I/O settings

Nontransferable parameters include:
• Serial Number
• Excitation Frequency
• Scale Factor

• Analog output calibration factors

(including custom offsets)