Updating endpoint firmware via rf – Badger Meter ORION AMR/AMI Hardware Solutions for Gas Utilities User Manual

Page 21

Advertising
background image

Updating Endpoint Firmware via RF

This section provides instructions for updating firmware for single or multiple endpoints using radio frequency (RF)

Update Firmware for a Single Endpoint via RF

1 On the main menu, select the Single Endpoint IR/RF Update button The button becomes green when selected
2 Select the RF radio button in the Update Method field

OTEE:

N

Make sure the ORION mobile transceiver and antenna are connected to the laptop, and the COM ports are

correctly set Refer to

"Settings" on page 13

Result: If it is not already displayed, the S/N field for the endpoint serial number appears as well as ”Waiting for

Mobile Message.“

3 Enter the endpoint serial number in the S/N field

Result: The software waits to receive communication from the endpoint.

Figure 19: RF Waiting for Mobile Message

When the mobile message is received from the endpoint, the Update button appears and is active.

Figure 20: Update via RF

4 Click Update

Result: The information on the screen updates, the Cancel button displays and the firmware update proceeds.

UPDATING ENDPOINT FIRMWARE

Page 21

April 2014

ORION®

SE/ME Firmware Updater

Advertising