7. With the torque wrench, tighten the casing bolt as

indicated in the chart below:

Meter

Ft-lbs

2-inch Turbo Series Meter

10.9

3-inch Turbo Series Meter

37.5

4-inch Turbo Series Meter

37.5

6-inch Turbo Series Meter

37.5

2-inch Compound Series Meter

16.7

3-inch Compound Series Meter

33.3

4-inch Compound Series Meter

33.3

6-inch Compound Series Meter

33.3

Heavy Duty Bypass M70

21.0

Heavy Duty Bypass M170

50.0

Note: If two ORION transmitters are required for a fire

series assembly or a compound meter application, the

transmitters must be mounted on opposite sides of the

meter head assembly.