background image

Removing the Low Flow Side

Follow same removal steps for the cover as listed in

“Removing the High Flow Turbo Meter Head Assembly” on page 12

Low Flow

Register

High Flow

Register

Cover Seal

Bypass Seal

Turbo Head

Assembly

Bottom Plate

Chamber

Assembly

Figure 13: Removing the low flow side

Servicing the Chamber and Disc

1 Remove the screws holding the bottom plate on the cover assembly
2 Remove the bottom plate
3 Remove the chamber retaining strap
4 Lift out the chamber and disc assembly
5 Inspect the chamber and parts (see

Figure 9

) for visible signs of wear The thrust roller and dovetail insert should be

replaced if worn Replace the chamber if wear is evident on disc spindle where it contacts the crossbar magnet drive or

the balls or if the disc plate is worn by foreign material If water deposits are found, remove any mineral deposits from

the disc and chamber interior surfaces Before replacing the chamber in the meter head, make certain that the area

surrounding the magnet in the meter head is clean