TRACE

®

is a registered trademark of American Meter Company. Badger

®

, Recordall

®

, ORION

®

,

and RTR

®

are registered trademarks of Badger Meter, Inc. Itron

®

and ERT

®

are registered

trademarks of Itron, Inc. TORX

®

is a Registered trademark of Camcar, Division of Textron, Inc.

Hexagram

®

is a trademark of Hexagram, Inc. RAMAR

®

is a trademark of RAMAR Technology.

Other trademarks appearing in this document are the property of their respective entities.

© 2012 Badger Meter, Inc. All rights reserved.

Due to continuous research, product improvements and

enhancements, Badger Meter reserves the right to change

product or system specifications without notice, except to the

extent an outstanding contractual obligation exists.

Badger Meter

| P.O. Box 245036, Milwaukee, Wisconsin 53224-9536

800-876-3837 | [email protected] | www.badgermeter.com

PIT INSTALLATIONS

Insert the entire splice assembly into the filled splice tube P/N 62085-

001 as indicated in Figure 6. Close the cover with leads exiting alternate

sides as indicated in the drawing.

TESTING

After connections are complete, test the entire installation including the

RTR, wiring, and remote or pit module for proper operation in accordance

with the instructions supplied with the module.

Install the RTR on the water meter and secure it using the TORX

®

screw

provided.

TROUBLE SHOOTING

An analog ohm meter will show an "open" reading when connected

across the OUTPUT leads of the RTR. When operating the RTR, the

ohm meter should show a momentary deflection toward zero when the

RTR sends a signal.

Figure 6. Splice Enclosure Assembly

RTR

®

with three wires (brown cable)

For connection to ORION

®

Transmitter, Hexagram

®

Star Module or RA-

MAR

®

V4 Transpondit, verify the RTR has a brown cable and contains

a label with either an 'HE' for connectivity to Hexagram or an 'RA' for

connectivity to RAMAR. Using the chart below, connect the RTR con-

ductors to the AMR module conductors using insulation displacement

gel-filled splices, P/N 59761-001 provided in the installation kit. Crimp

the cables completely using a parallel jaw crimper, P/N 59983-001.

For connection to an Itron

®

remote ERT

®

, verify that the RTR has a brown

cable and contains an 'IT' on the label. For more information on the

installation instructions for the Itron remote ERT, please refer to Itron's

Installation Remote ERT Modules 40W-1 and 50W-1.

Figure 4. 3 Conductor RTR Splice Installation Diagram

Hexagram

Itron

RTR

ORION

Ramar V4

Pit/Remote

Remote

Red Red Wire

#2

Red Red

Black Black Wire

#3

Black Black

Green Green Wire

#1 White Green

If the wire is cut or broken and requires a field splice after initial

installation, connect like colors to maintain proper installation.

Place the two plastic cable ties P/N 34776-001 on wires and tighten

securely for strain relief. Remove excess cable tie with wire cutting

device.

CABLE TIES

(Remove Excess)

GEL-SPLICE

Figure 5. Splice Installation Diagram