Specifications – Badger Meter QuikSert User Manual

Page 7

Advertising
background image

SPECIFICATIONS

Physical
Installation

Mounts between 2 inch ANSI raised face flanges . Horizontal or vertical mounting

Flow Range/Nominal K Factors

See pressure drop graphs

Low Range

7…70 acfm (10…100 mcfd)/365 pulses per acf (12,900 pulses per m

3

)

Mid Range

14…210 acfm (20…300 mcfd)/190 pulses per acf (6710 pulses per m

3

)

High Range

35…350 acfm (50…500 mcfd)/85 pulses per acf (3000 pulses per m

3

)

Working Pressure

Vacuum to 2220 psig (15 .3 MPa)

Pressure Drop

3 inches of water column (7 .5 mbar) at maximum rated flow (dry air)

Pressure Port

1/8 inch NPTF (plugged)

Temperature

–40…330° F (–40…165° C)

Electrical
Output Voltage

100 mVp-p minimum when used with Blancett B111113 magnetic pickup

Accuracy
Linearity

± 2% of reading over the specified measurement range

Uncertainty

± 1% of reading (when calibration data is entered into an intelligent Blancett

monitor/transmitter)

Repeatability

± 0 .5%

Certifications

Intrinsically Safe

Class I Division 1 Groups C, D
Entity parameters with Blancett B111113 magnetic pickup installed for US and Canada .

Complies with UL 913 and CSA 22 .2 No . 157-92
V

max

= 10V

I

max

=

3 mA

Ci

=

0 µF

Li

=

1 .65 H

Explosion Proof

Class I Division 1 Groups C, D . Complies with UL1203 and CSA C22 .2 No . 30-M1986

Single Seal

Complies with ANSI/ISA 12 .27 .01-2003

Construction
Body and Cartridge

316/316L stainless steel

Bearing Mounts

304 stainless steel

Set Screws – Pressure Port Plug

316 stainless steel

Bearings and Rotor Shaft

Tungsten carbide

Rotor

410 stainless steel

Connections
Pickup

Mates with AN3106A-10SL

Conduit

1 in . NPT (25 .4 mm)

User Manual

Page 7

June 2014

Advertising