Specifications – Badger Meter Irrigation Sensors - 1/2 and larger" User Manual

Page 13

Advertising
background image

Installation & Operation Manual

2. If you suspect that the sensor is bad, you can test the

monitor circuitry by connecting a piece of wire to one
of the sensor input terminals and tap the other side of
the wire to the other sensor input terminal. Shorting
across the sensor input terminals ON and OFF
repeatedly allows the display to respond by trying
to calculate a flow rate for the frequency of your
shorting action. If the display does not show a change
from 0.00, it indicates a problem with the monitor.

3. If the monitor tests ok and there are any splices in the

cable, break the sensor cable at the splice closest to
the sensor and retry the shorting test in step 2.

4. If the cable tests ok, drain the pipe line, verify the

pressure is off, remove top lock nuts holding the
sensor electronics. Spin the impeller by hand. If flows
are noted on the display, and impeller spins freely
then the flow rates may have been below our design
minimums or the line was full of air. Try again. If the
sensor fails to respond then replace sensor.

SPECIFICATIONS

Wetted Materials for all sensors

See Technical Brief for material specifics

Sensor Sleeve and Hex Adapter for 220BR, 225BR, and

226BR

Sleeve: admiralty brass, UNS C44300; hex adapter:
valve bronze, UNS C83600

Sensor Sleeve and Hex Adapter for 220SS and 226SS

Series 300 stainless steel

Temperature Ratings

Standard version: 2210F (1050C) continuous service

High temperature version: 2850F (140.60C) continuous
service; 3050F (1500C) peak temperature (limited
duration)

Pressure Ratings

At 1000F

At 3000F

220SS

400 psi

325 psi

220B

400 psi

325 psi

225B

300 psi

210 psi

226B

400 psi

250 psi

226SS

400 psi

300 psi

Recommended Design Flow Range

0.5 to 30 ft/sec

Initial detection below 0.3 ft/sec

Accuracy

± 1.0% of full scale over recommended design flow
range

Repeatability

± 0.3% of full scale over recommended design flow
range

Linearity

± 0.2% of full scale over recommended design flow
range

Transducer Excitation

Quiescent current 600uA@8VDC to 35VDC max.

Quiescent voltage (V

high

)

Supply Voltage -(600uA*Supply impedance)

ON State (V

Low

) Max. 1.2VDC@40mA current limit

(15ohm+0.7VDC)

Output Frequency

3.2 Hz to 200 Hz

Output Pulse Width

5 msec ±25%

Electrical Cable for Standard Sensor Electronics

20 feet of 2-conductor 20 AWG shielded U.L. type
PTLC wire provided for connection to display or
analog transmitter unit. Rated to 1050C. May be
extended to a maximum of 2000 feet with similar
cable and insulation appropriate for application.

Electrical Cable for IR Sensor Electronics

48 inches of U.L. Style 116666 copper solid AWG 18
wire with direct burial insulation. Rated to 1050C.

Page 13