Installation instructions, double support – Badger Meter ASF - Steam (2 to 48")" User Manual

Page 6

Advertising
background image

INSTALLATION INSTRUCTIONS, DOUBLE SUPPORT

1 . Follow steps 1 through 4 in

"Installation Instructions, Single Support" on page 5

. At 180° from and on the same plane

as the previously drilled hole, grind the surface of the pipe to provide a clean area for welding . Drill a hole and deburr,

especially on the inside of the pipe . Size the hole used for the double support according to

Table 3

.

Model / Sensor

Weld Connector

Drill Bit

ASF (7/8")

1/2"

1/2"

ASF1 (1-1/4")

1"

7/8"

ASF2 (2-1/4")

3"

2-3/4"

Table 3: Double support drill bit size

2 . Weld the double support weld-o-let, making sure that it is centered with the drilled hole (1/16" weld gap recommended) .
3 . Install the ASF Ellipse sensor through the two holes . Make sure that the double support pin passes through the guide ring .

See

Figure 5

.

Ellipse Sensor

Double Support Pin

Guide Ring

Figure 5: Double support pin

4 . While holding the ASF Ellipse in its fully inserted position, align the sensor head with the direction of flow as in step 7,

"Installation Instructions, Single Support" on page 5

.

5 . Check that the ASF Ellipse is in the correct orientation and spans the inside of the pipe . Tighten the compression nut

manually, the tighten it another 1-1/4 turns using a wrench .

6 . Install the plug into the end of the double support weld-o-let . Tighten the plug to prevent leakage . Make sure that there is

no leakage in the system .

7 . Follow steps 8 through 13 in

"Installation Instructions, Single Support" on page 5

.

TYPICAL INSTALLATION WITH DIFFERENTIAL PRESSURE TRANSMITTER

Horizontal Pipes

Vertical Pipes

PIPE

FILL HERE W/WATER

1/2" TUBING

3- or 5-VALVE

MANIFOLD

DP. TRANSMITTER

ELLIPSE

SENSOR

CROSS TEES

Figure 6: Typical installation

Ellipse® Pitot Tube Meter, ASF Annular Flanged Steam Meter

Page 6

April 2014

Advertising