PIPE ORIENTATION AND SENSOR MOUNTING

Figure 2: Orientation and mounting

INSTALLATION INSTRUCTIONS, SINGLE SUPPORT

1 . Choose the proper location to install the AHR Ellipse using AGA/ASME standards (or equivalent) . See

“Location Instructions”

on page 6

.

2 . Grind the surface of the pipe where the AHR Ellipse is to be inserted to provide a clean area for welding .
3 . Weld the supplied weld-o-let to the pipe using standard codes for your application . Protect the threads during the

welding process .

4 . Thread the close (short) nipple into the weld connector . Install the supplied 3-piece isolating ball valve .
5 . Open the isolating ball valve . Mount the high-pressure drilling machine onto the ball valve . Drill a hole through the pipe

wall according to the following table .

Model / Sensor

Weld Connector

Drill Bit

AHR (7/8")

1-1/4"

1-1/8"

AHR1 (1-1/4")

1-1/2"

1-3/8"

OTEE:

N

There is no need for a drilling machine if it is not a hot tap installation or if the system is not pressurized .

6 . Withdraw the drill bit through the isolating ball valve . CLOSE the ball valve and dismantle the drilling machine . Make sure

there is no leakage at the valve and close nipple connections . The ball valve is to remain completely closed until step 10 .

7 . Thread the supplied cage (long) nipple into the isolating ball valve . Install the supplied reducer (1-1/4" x 1" coupling) on

the cage nipple .

8 . Thread the supplied packing gland onto the reducer .
9 . Install the instrument valves (optional) at the pressure connections on the AHR head . Make sure the valves are FULLY

CLOSED before proceeding .

10 . Insert the Ellipse AHR through the packing gland and cage nipple until it reaches the isolating ball valve . Slightly tighten

the compression nut of the packing gland and attach the safety chain to the AHR . Open the isolating ball valve and push

the sensor down by hand until it reaches the opposite side of the pipe .

Ellipse® Pitot Tube Meter, AHR Annular Low Pressure Wet Tap Meter