1 The primary station can be installed in any position on vertical or horizontal lines However for best result, on horizontal

liquid lines where the risk of air/gas entrapment in the meter tubing is prevalent, install the element with the head under

the horizontal centerline For horizontal air or gas lines the head should be above the center line to prevent condensation

2 Leave the protective caps in place to protect the valves against construction debris, dust, paint, and other contaminants

Close the valves after installation to prevent leakage on startup

3 For pipes 2…6":

a Pipes 2", 2-1/2", 3", 3-1/2" and 4", drill a 3/8" hole into pipe
b Pipes 5" and 6", drill a 7/16" hole
c Weld the coupling to the pipe in line with the hole
d Pass the probe through the packing gland and insert it into the pipe through the coupling Tighten hex nut to

the coupling

e Push the probe until it touches the opposite side of the pipe and tighten hex nut of the packing gland

6 For pipes 8…24" with double support:

a Pipes measuring 8" and 10": Drill a 1/2" hole on side where reading will be taken and 13/32" on other side

Pipe measuring 12": Drill a 5/8" hole on side where reading will be taken and 17/32" on other side

Pipe measuring 14" and 16": Drill a 7/8" hole on side where reading will be taken and 25/32" on other side

Pipe measuring 18", 20" and 24": Drill a 1-1/8" hole on side where reading will be taken and 1-1/16" on other side

b Weld a coupling to the pipe in line with the hole making sure it is in line with opposite hole
c Pass the probe through the packing gland and insert it into the pipe through the coupling Tighten hex nut to

the coupling

d Push the probe through the pipe until it passes through opposite hole to ensure alignment
e Withdraw probe and weld other coupling to the pipe
f Push the probe through the packing gland until it enters other hole and is flush with outside wall of the pipe and

tighten hex nut of the packing gland

g Install the plug into the coupling