Introduction, Specifications – Badger Meter Model BHR User Manual

Page 3

Advertising
background image

INTRODUCTION

The Preso patented elliptical design outperforms and provides greater

accuracy than traditional differential pressure flow measurement devices . This

differential pressure flow meter is designed with a series of ports facing the

upstream velocity pressures, as well as flow sensing ports strategically located

ahead of the trailing edge flow separation .
The multi-ported, self-averaging flow element consists of an elliptical shape

with two independent flow sensing chambers . The impact velocity sensing

holes (high pressure) are located along the leading edge and the true static

sensing holes (low pressure) are on the exterior probe side . Model BHR comes

with instrument shutoff valves that can be plumbed to a transmitter or direct

indicating gauge .

True static

sensing holes

Impact velocity

sensing holes

Figure 1: BHR pressure sensing holes

SPECIFICATIONS

Applications

Liquids and gases

Pipe Sizes

2…24 inches (50…610 mm)

Pressure

75 psi (517 kPa) maximum

Temperature

120° F (49° C) maximum

Accuracy

±0 .75% of reading

Turndown Ratio

17:1 with no vacuum effect

Standard Components

Y-type head, brass 1/8" FNPT connection
Sensor connection:
2"…5", Ellipse 1/2"; 3/4" Brass compression fitting with SS ferrule
6"…12", Ellipse 7/8"; 1" Brass compression fitting with SS ferrule
14"…24", Ellipse 1-1/4"; 1-1/4" Brass compression fitting with SS ferrule
CS 3000 lb thread fitting – ASTM A105
316/316L SS Ellipse sensor
Instrument valves (2 per sensor) – 1/4" SAE flare brass ball type
Polycarbonate ID tag with wire
Bronze isolation ball valve

Reynolds Number

Greater than 75,000 maintains most accurate flow measurements
Less than 75,000 consult factory for estimated results

Resonance

If greater than 0 .8, use double support

Table 1: Specifications

User Manual

Page 3

April 2014

Advertising