Servicing – Badger Meter Disc Meter User Manual

Page 10

Advertising
background image

Electronic Calibration

If electronic scaling is the accessory medium for calibration, see the accessory technical brief for instructions .

Servicing

The following instructions are for removal, inspection and installation of meter parts and assemblies . Refer to applicable

illustrated parts list for part numbers of components and ordering information . Accessory service and repair procedures are

provided in literature specific to that device .

Meter Disassembly Method

These procedures are for disassembly of the meter:

1 . Shut off the fluid flow to meter . Place a container under the meter and relieve fluid pressure in the meter by uniformly

loosening the bolts (bronze meter) or the retaining ring (plastic meter) . Fluid will run out into the container .

2 . Remove the bolts or the retaining ring while holding the housing bottom in place . Remove the housing bottom . The

chamber assembly may drop from the housing as the bottom is removed .

3 . If the chamber assembly is out, set it aside . If not, first remove the chamber strap and then remove the

chamber assembly .

4 . Remove the meter screen . Inspect the screen for dirt and corrosion . Clean or replace the screen as necessary .
5 . Inspect the chamber assembly:

a . Check the disc in the chamber assembly for warpage, cracks or wear . A severely worn disc can cause

over-delivery of the fluid being metered .

b . Check the thrust roller and thrust roller insert for excessive wear .

After inspection, clean or replace the chamber assembly as necessary . If the chamber is worn or corroded, replace the entire

chamber and disc assembly .

6 . Re-install the housing chamber assembly, screen, chamber strap and bottom as follows:

a . Assemble the screen in the proper location .

b . Position the chamber assembly in the proper orientation . Add the chamber strap .

c . Position the housing bottom with the correct seal . (Replacement of seal is always recommended .)

d . Assemble and tighten the bolts or retaining ring .

Alternative Disassembly Method for Service

Loosen all the connection pieces slightly . Turn the meter upside-down, putting gravity on your side . This will help eliminate

the possibility of the chamber assembly and or the screen component dropping during disassembly and causing damage .

Recalibration

After repairing or replacing a meter component or assembly, perform the calibration check and adjustment procedure to

ensure that the meter is properly calibrated and will operate in accordance with published specifications .

www.badgermeter.com

Recordall is a registered trademark of Badger Meter, Inc. Other trademarks appearing in this document are the property of their respective entities.

Due to continuous research, product improvements and enhancements, Badger Meter reserves the right to change product or system specifications without notice, except to the extent an outstanding

contractual obligation exists. © 2013 Badger Meter, Inc. All rights reserved.

The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411

Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-04 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter | Rm 501, N° 11 Longyue Apartment | N° 180 Longjin Rd, Jiuting Songjiang District | Shanghai, China | 201615 | +86-21-5763 5412

Advertising