Electrical connections, Specifications, Operation guidelines – Badger Meter Vision User Manual

Page 2: Output signal, Wiring diagram, Cable connection

Advertising
background image

www.badgermeter.com

Trademarks appearing in this document are the property of their respective entities. Due to continuous research, product improvements and enhancements, Badger Meter reserves

the right to change product or system specifications without notice, except to the extent an outstanding contractual obligation exists. © 2014 Badger Meter, Inc. All rights reserved.

The Americas | Badger Meter | 4545 West Brown Deer Rd | PO Box 245036 | Milwaukee, WI 53224-9536 | 800-876-3837 | 414-355-0400

México | Badger Meter de las Americas, S.A. de C.V. | Pedro Luis Ogazón N°32 | Esq. Angelina N°24 | Colonia Guadalupe Inn | CP 01050 | México, DF | México | +52-55-5662-0882

Europe, Middle East and Africa | Badger Meter Europa GmbH | Nurtinger Str 76 | 72639 Neuffen | Germany | +49-7025-9208-0

Europe, Middle East Branch Office | Badger Meter Europe | PO Box 341442 | Dubai Silicon Oasis, Head Quarter Building, Wing C, Office #C209 | Dubai / UAE | +971-4-371 2503

Czech Republic | Badger Meter Czech Republic s.r.o. | Maříkova 2082/26 | 621 00 Brno, Czech Republic | +420-5-41420411

Slovakia | Badger Meter Slovakia s.r.o. | Racianska 109/B | 831 02 Bratislava, Slovakia | +421-2-44 63 83 01

Asia Pacific | Badger Meter | 80 Marine Parade Rd | 21-06 Parkway Parade | Singapore 449269 | +65-63464836

China | Badger Meter | 7-1202 | 99 Hangzhong Road | Minhang District | Shanghai | China 201101 | +86-21-5763 5412

Control. Manage. Optimize.

ELECTRICAL CONNECTIONS

Output Signal

The output signal is a square wave signal where the frequency is proportional to the flow rate. An external, user-supplied

pull-up resistor is required to ensure that the open collector will sink less than 20 mA. Applying a current greater than 20 mA

may damage the sensor.

Wiring Diagram

1.2. . .2.2K Ohms

Customer Supplied

5. . .24 V DC

0 V DC

OUTPUT

With DIN Connector

Cable Connection

Bro

wn Black

Red

5. . .24V DC

0V DC

Function

DIN Termination

V+

1

Output

2

SPECIFICATIONS

Model

BV1000

BV2000

025

050

075

100

150

250

350

Flow

Range

0.026…0.65 gpm

0.13…1.3 gpm 0.13…2.0 gpm

0.26…2.7 gpm

0.26…4.0 gpm

0.26…6.6 gpm 0.53…9.2 gpm

0.1…2.5 lpm

0.5…5 lpm

0.5…7.5 lpm

1…10 lpm

1…15 lpm

1…25 lpm

2…35 lpm

K-Factor

70,000 ppg

26100 ppg

17800 ppg

12500 ppg

8300 ppg

3785 ppg

2840 ppg

18,500 ppl

6900 ppl

4700 ppl

3300 ppl

2200 ppl

1000 ppl

750 ppl

Frequency

Output

30…770 Hz

58…575 Hz

38…575 Hz

55…550 Hz

37…550 Hz

17…416 Hz

25…437 Hz

OPERATION GUIDELINES

• Do not exceed the specific indications.
• The Vision Series meter is a volumetric measuring device. Any air/gas in the liquid will be included in

measured volume.

• Correctly installed, the sensor is maintenance free.
• Do not blow out the turbine flow meter with compressed air. This may damage the bearings.

Advertising