Registration Information

The Registration Information screen selects the option to collect registration information for each dispense order The options

are YES and NO (default)

Regist. Info

YES / NO

1 Use the Scroll key to move the cursor to either YES or NO
2 Press Enter to advance to the Keypad Timeout screen

Keypad Timeout

Timeout parameter corresponds to the time it takes to validate after all dispense order data has been entered If the Enter

button is not pressed within the time allocated, the keypad display goes back to initial menu and the input data is erased

The Keypad Timeout is between zero to 255 seconds (0 = no timeout) and the default for this feature is 10 seconds

Keypad timeout

10-

1 Press the Backspace key to erase the current setting
2 Type in the new setting
3 Press Enter to advance to the Topoff Timer screen

Topoff Timer

This is the time a user has to top-off a dispense after the complete preset batch has been dispensed

If a user has not pressed reset on an RF Meter/Hose within the topoff period, the RF Meter/Hose transmits the dispensed

order quantity to the keypad and locks out the RF Meter/Hose

The topoff time is equal to one second for each count For example, 600= 600 seconds or 10 minutes

The topoff timer can be set from zero to 15 minutes

Topoff Timer

0--

1 Press the Backspace key to erase the current setting
2 Type in the new setting
2 Press Enter to advance to the Internal Printer screen

Internal Printer

Use the Internal Printer screen to print dispense ticket information

Internal Printer

YES / NO

1 Use the Scroll key to move the cursor to either YES or NO

To print the dispense ticket on the keypad printer, set this option to

YES

To print to a remote printer or to not print a ticket, set this option to

NO

2 Press Enter to advance to the External Printer screen

External Printer

The External Printer (EPSON LX-300) screen is used to print the report information This must be set to YES to print reports

External Printer

YES / NO

NOTE:

N

External printer must be set to No to select

the Barcode Scanner

1 Use the Scroll key to move the cursor to either YES or NO
2 Press Enter to accept the setting and advance to the next screen

If you select YES, the display advances to the New Superv. PW

screen

If you select NO, the display advances to the Barcode Scanner

screen