A-100ne, Fvs) flow verification system, 2 mode 0 - tfd and fvs system set-up – Blue-White A-100N FLEXFLO Peristaltic Pump User Manual
Page 11: Tfd (tube failure detection), Page 10, This shroud
 
A-100NE
Page 11
Confirm the FVS flow range - The Flow 
Verification Sensor (FVS) will only function 
within its operating range. Sensor model FV-
100-6V has an operating range of 30-300 
ml/min (1-10 oz/min). If the pump’s output is 
less than 30 ml/min (0.5 ml/sec), the sensor 
will not detect chemical and a signal will not 
be sent to the pump. 
OPERATING
FLOW RANGE
(ml/min)
30-300
FV-100-6V
100-1000
FV-200-6V
200-2000
FV-300-6V
300-3000
FV-400-6V
500-5000
FV-500-6V
700-7000
FV-600-6V
SENSOR
MODEL
NUMBER
Install the FVS Flow Sensor - The Flow Verification Sensor (FVS) should 
be installed on the inlet (suction) side of the pump tube. The sensor includes 
a PVC tubing insert, located inside the sensor’s female thread connection, 
that is designed to seal the sensor onto the pump tube inlet adapter. Thread 
the sensor onto the pump tube until the tubing insert is snug against the 
pump tube inlet fitting - do not over-tighten.
Connect the red/white, black, and white wires from the sensor to the red, 
black, and yellow wires located in the pump’s junction box. See page 7.
Contact Closure Alarm Output - A contact closure output (relay) is 
provided with the FVS system. The relay can be configured for normally 
open (factory default) or normally closed operation by properly positioning 
the connector plug on the circuit board (see page 7). 
!
(FVS) Flow Verification System
The A-100NE is equipped with a
Flow Verification System which is designed to stop the pump and provide a 
contact closure output in the event the sensor does not detect chemical 
during pump operation. This could indicate a clogged injection fitting, 
empty chemical solution tank, worn pump tube, loose tubing connection, 
etc. 
To allow the pump to clear any gasses that may have accumulated during 
stopper operation (such as with chlorine), an alarm delay time value from 1-
256 seconds must be programmed (An alarm delay value of 000 seconds 
disables the FVS system). The pump will stop, and the alarm mode 
activated, if no pulses are received by the pump and the alarm delay time 
period has ended. Press the STAND-BY button twice to clear the alarm and 
restart the pump. The Flow Verification Sensor is sold as an optional 
accessory.
-
Inlet Adapter
Outlet Adapter
RUN
STANDBY
RUN
FIELD
DIGIT
MODE
PROGRAM
STAND-BY
PRIME
MINIMUM
MAXIMUM
INPUT MODES
1 - MANUAL
2 - 4-20mA
3 - 0-10VDC
4 - 0-1000 Hz
PROGRAM
RESET SERVICE
PRIME
DISPLAY
DIGITAL TIMER PUMP
1000
MODE
5 - PULSE (BATCH)
FVS Sensor
6.2 MODE 0 - TFD and FVS system set-up
Mode 0 is used to program the TFD (Tube Failure Detection) system and 
the FVS (Flow Verification System). 
!
TFD (Tube Failure Detection)
-
Tube Failure Detection System which is designed to stop the pump and 
provide a contact closure output in the event the pump tube should rupture 
and chemical enters the pump head. This patented system is capable of 
detecting the presence of a large number of chemicals including Sodium
The A-100NE is equipped with a
A-100NE
Page 10
Chemical
Tubing failure
Hypochlorite (Chlorine), Hydrochloric 
(muriatic) Acid, Sodium Hydroxide, and 
many others. The system will not be 
triggered by water (rain, condensation, etc.) 
or silicone oil (roller and tubing lubricant). 
If the system has detected chemical, the 
pump tube must be replaced and the pump 
head and roller assembly must be 
thoroughly cleaned. 
Confirm Chemical Detection - To determine if your chemical will be 
detected by the system, remove the pump tube and roller assembly. Place a 
small amount of the chemical in the bottom of the pump head - just enough 
to cover the sensors. Turn on the pump. If the TFD system detects the 
chemical, the pump will stop after a five second confirmation period and 
the ALARM icon will light on the display. If the TFD system does not 
detect the chemical, the pump will continue to run after the confirmation 
period. Carefully clean the chemical out of the pump head being sure to 
remove all traces of chemical from the sensor probes. Press the 
RUN/STAND-BY button to clear the alarm condition and restart the pump. 
Contact Closure Alarm Output - A contact closure output (relay) is 
provided with the TFD system. The relay can be configured for normally 
open (factory default) or normally closed operation by properly positioning 
the connector plug on the circuit board (see page 7). 
This Shroud
is designed to weather proof this Peristaltic Pump. If the
pump is wall mounted the shroud is not necessary and will still be 
considered weather proof. 
Floor Mount
Weather proof
Weather proof
Shroud
Wall Mount