6.5 Mode 3 - 0-10V DC input -

In this mode, the on-time of the cycle

will automatically adjust to match the received VDC input value. When the
VDC value is equal the programmed maximum, the pump will run
continuously.
Four values must be programmed:
1) ON-T = The amount of time the pump will run, per cycle, when the

minimum VDC value is received. (Typically programmed to zero)

2) VDC minimum = The VDC input value that will result in the on time

(ON-T). (Typically programmed to 0 VDC)

3) TOT-T = The total cycle time.
4) VDC maximum = The VDC input value that will result in the pump

running continuously.

Example:
ON-T setting = 0 seconds
VDC minimum setting = 0 VDC
TOT-T setting = 6 seconds
VDC

maximum setting = 7.5 VDC

A-100NE

Page 16

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

3

00.0

MODE

ON-T

SEC

+ Set the pump for mode 3. Press the

MODE button until MODE 3 is shown on
the LCD display.

+ Enter the programming mode. At the

same time, press the RUN/STANDBY
button and the MODE button. A blinking
ARROW will point to the word
PROGRAM indicating the program mode
has been activated. The on time ON-T

icon will blink. The currently selected time unit icon will be displayed.
The current on time setting will be displayed and the left most (selected)
digit will blink. The decimal is fixed and cannot be moved.

+ Pressing the DIGIT button will increase the selected digit.
+ Pressing the FIELD button will select a new the digit to the right or the

time unit.

+ Press the DIGIT button to increase the selected digit or time unit.

1

0

2 3

5 6 7 8

10

0

1.5

3.0

4.5

6.0

Pump Run-T

ime (Sec.)

DC voltage input (VDC)

4

9

A-100NE

Page 17

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

3

00.0

MODE

SEC

TOT-T

+ Press the MODE button to exit the on time

programming screen and enter the

minimum programming screen. The VDC
icon will blink. A blinking ARROW will
appear next to the word MINIMUM. The
current minimum VDC setting will be
displayed and the left most (selected) digit

VDC

will blink.

+ Pressing the DIGIT button will increase the selected digit.

total time TOT-T icon will blink. The currently selected time unit icon will
be displayed. The current total time setting will be displayed and the left
most (selected) digit will blink. The decimal is fixed and cannot be
moved.

+ Pressing the DIGIT button will increase the selected digit.

+ Pressing the FIELD button will select a

new the digit to the right.

+ Press the DIGIT button to increase the

selected digit.

+ Press the MODE button to exit the VDC

minimum programming screen and enter
the total time programming screen. The

+ Pressing the FIELD button will select a

new the digit to the right or the time unit.

+ Press the DIGIT button to increase the

selected digit or time unit.

+ Press the MODE button to exit the total

time programming screen and enter the
VDC maximum programming screen. The
VDC icon will blink. A blinking ARROW

will appear next to the word MAXIMUM. The current maximum VDC
setting will be displayed and the left most (selected) digit will blink.

+ Pressing the DIGIT button will increase the selected digit.
+ Pressing the FIELD button will select a new the digit to the right.
+ Press the DIGIT button to increase the selected digit.
+ At the same time, press the RUN/STANDBY button and the MODE

button. A blinking ARROW will point to the word RUN indicating the run
mode has been activated.

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

3

9.5

MODE

VDC

RUN

PROGRAM

STAND-BY

PRIME

MINIMUM

MAXIMUM

3

0.0

MODE

VDC