Dwyer 1207A User Manual

Page 19

Advertising
background image

1207A manual

Page 19

STANDARD COMBUSTION PRINTOUT

DWYER

1207A

1.0

/product

code

Serial

No.

123456789

/serial

number

/user header 1

/user

header

2



DATE

11/01/09

TIME

09:53:23



..............................................

FUEL

NATU GAS


O2 %

5.1

CO2 %

9.0

CO ppm

400

NO

ppm n/f

/NO

sensor

not

fitted

FLUE

o

F 48

INLT

o

F 15

NETT

o

F 33


EFF

(C)

102.1

/condensing

efficiency

PRS INWG

0.001

Losses %

-2.1

XAIR %

32.1


CO/CO2 0.0044
PI

0.44

O2 ref %

0.0



SMOKE......................................


....................................................