FUTEK IPM500 (D500) Digital Display User Manual

Front, Spec. system, Back

Advertising
background image

FRONT

Copyright 2007 Futek Advanced Sensor Technology, Inc.

DOC. No. MKTSFIPM01172007

www.futek.com Tel: 1-800-23-FUTEK or 949-465-0900 [email protected]

STANDARD FEATURES:

Up to 60 Conversions per second

Scaleable to 5 digits. ±99,999

Worldwide input power: 85 to 264 VAC

and 90 to 370 VDC (

Green

or

Blue

Connector)

Isolated selectable excitation to power sensors.
5VDC@200 mA, *10 VDC@120 mA

Peak hold and remote auto tare

Plug-in screw terminal

Weight 9 oz [0.25 Kg]

*10 VDC@120 mA is optional

IPM500/IBT500 QUICK START

Menu Button

Is used to scroll through
setting options and to
save individual settings.

Peak Button

Is used to select the dis-
played menu item. Pressing
the

Peak function on a me

item will enable the user to
change the items setting.

Reset Button

Is used to reset all display func-
tions. Selecting the Reset function
can change the numerical value of

by the

Peak function.

Alarms Button

Allows the user to scroll
backwards through the
menu options.

ENVIRONMENT:

OPERATING TEMP. 32°F to 130°F [0°C to 55°C]

STORAGE TEMP.

-100°F TO 180°F [-73

[[ °C t

C o

tt 82°C]

C

C

RELATIVE HUMIDITY 95% AT 100°F [38°C]

Panel

Securing

Screws

SPEC.

SYSTEM

TORQUE

SENSOR

PRESSURE

SENSOR

LOAD

CELL

&

FORCE

SENSOR

Signal Out

(Analog or

RS232 or

RS485

Power

connector

connector

connector

Power Supply

Scope or DMM

Data Acquisition Card

Computer

VAC 85 to 264 (Std)

VDC 9-37 (Opt)

connector

Futek VCal Sensor

OPTIONS:

* Analog Output

* Alarm/Relay

* RS232 / USB & TEDS

* RS485

* DC option (9-37 VDC)(Black or

Brown

Connector

)

*

RS232 / USB Software Available

1.772

[45 ]

+0.6

-0.0

+0.024

-0.0

3.622 [92

]

+0.032

-0.0

+0.8

-0.0

Panel Cutout

LED

Alarm 2

LED

Alarm 1

3.78 [96]

4.02 [102]

1.89

[48]

0.197

[5]

J1

J2

J3

BACK

J4

J5

IPM500 Also Available In Bench

Top Version (IBT500)

Power Source

Tare Switch

1

AC HI (+DC HI)

2

AC LO (DC RET)

3

EARTH GROUND

4

DIGITAL INPUT B

5

DIGITAL INPUT A

6

DIGITAL GROUND

Black

White

Green

J1

Power/Input Connections

1

Alarm1 - N/O Contact

2

Alarm1 - N/C Contact

3

Alarm1 - Common

4

Alarm2 - N/O Contact

5

Alarm2 - N/C Contact

6

Alarm2 - Common

J2

Alarm Output Connection

Alarm

Indicator

Power

Supply

1

0-20mA Output

2 0-10VDC Output
3 Isolated Ground

J4

- Excitation

1

- Sense

2

- Signal

3

+ Signal

4

+ Excitation

5

+ Sense

6

J5*

Sensor Connections,

6

-Wire

Black

White

Gry/Ylw

Red

Blue

Orange

- Excitation

1

- Sense

2

- Signal

3

+ Signal

4

+ Excitation

5

+ Sense

6

J5*

Black

White

Gry/Ylw

Red

Sensor Connections,

4

-Wire

RS232

or

RS485

J3

Analog Output

J5 Note:

* Color code shown below is per Futek standard wiring.

* Check your sensor color code per Futek spec drawing sheet.

Follow your sensor color code if it differs from the code below.

Jumper

Jumper

TEDS (IEEE 1451.4):

* TEDS option available for Futek IPM500

display, IBT500 display, VCal

TM

System

and all sensors.

* Futek also upgrades your existing sensors

with TEDS option.

* Call 1-800-23-FUTEK for details

or USB)

USB
or

or
TEDS

*

*

*

* For Serial # 0-227233

Advertising
This manual is related to the following products:
Table of contents