FUTEK LLB Series User Manual

Drawing number: f3131, Cautions mounting

Advertising
background image

90°

This drawing is submitted solely for the information and

exclusive use of the original addressee. It is not to be divulged

in whole or in part, by any firm or individual without written

permission from FUTEK

Drawing Number: F3131

RECESSED

PLATE

RETAIN WITH

SET SCREW

CAUTIONS

MOUNTING

MAINTAIN CLEAN
SURFACE

SUPPORT ON THE
OUTER RING ONLY.

1) DO NOT PULL ON OR CARRY SENSOR BY CABLE.

2) BE CAREFUL NOT TO APPLY EXCESSIVE FORCE ON
OR MOUNT ANYTHING IN CONTACT OF THE
DIAPHRAGM AREA.
3) ANY TAMPERING OR REMOVAL OF COVER, CABLE
AND/ OR CONNECTOR WILL VOID WARRANTY
4) ALWAYS HAVE SENSOR PLUGGED IN DURING
INSTALLATION TO MONITOR OUTPUT TO AVOID
PERMANENT ZERO SHIFT AND OVERLOAD.

LOAD SHOULD BE

APPLIED IN LINE

LOAD SHOULD BE

APPLIED ON THE

CENTER OF THE
BUTTON

SECURE FROM

OUTER LIP

LOAD BUTTONS ARE USED IN

THE MONITORING OF FORCE
APPLIED IN PRESS TYPE
APPLICATIONS.

FIXTURE MUST NOT

CONTACT DIAPHRAGM

AREA

FIXTURE LOAD SURFACE
MUST BE IN LINE WITH THE

SENSOR

SENSOR CAN NOT BE

USED IN TENSION.

SIDE LOAD MAY DAMAGE
THE SENSOR

THREADED LOAD PROBE TYPE

STANDARD

FLAT AND EVEN SURFACE
REQUIRED

1

2

4

3

6

5

7

8

FURTHER MOUNTING SUGGESTIONS

DIAPHRAGM

DIAPHRAGM

DIAPHRAGM

MOUNT IN

C'BORE HOLE

MOUNT USING

THREAD HOLES

SENSOR MAY BE

USED TO
MONITOR
FORCES
IN AN ARBOR
PRESS

DIAPHRAGM

Advertising