Switching from NORDAC trio SK ….. TR

to SK 200E, SK 300E or terminal box

To switch from NORDAC trio TR to SK 200E or SK300E inverter, it is necessary to
disassemble the TR inverter completely with adapter plate, and the motor terminal block
must be mounted.

The thermoswitch TF (terminals TP1 and TP2) and winding’s ends are to be connected to
the terminal block. The norm motors cables are marked as follows: U (white), V (red), W
(black) and have to be connected in correct way to the terminal block.




The winding’s begins will be connected to terminals U1, V1, W1 and the winding’s ends -
terminals U2, V2 and W2 (see photo).
For thermoswitch (TF) an additional terminal is available.

According to nameplate or characteristics the motor will be connected in star or delta to the
terminal block.

The assembly of SK 200E is to be done according to BU 0200 assembly instruction.
The assembly of SK 300E is to be done according to BU 0300 assembly instruction.


For motors of size 63, 71, 112 and partly 80 and 100

additional adapters are required for mounting SK 200E resp. SK 300E.