Type ETO2

OPEraTIOn

ETO2 is equipped with an easily operated encoder button (turn and press) and a display which describes the current situation. The

display is backlit and is illuminated by pressing the encoder button (OK). The illumination is automatically switched off after 30 seconds.

Press the encoder button and the main menu will be shown on the display.

Turn the button to scroll through the options. Not all the options are shown on the display at once, but they can be accessed by turning

the encoder button.

Press OK to select a highlighted option.

MaIn MEnu

ZOnE 1

Off

ZOnE 2

Off

sEnsOr 1

##.#°C

sEnsOr 2

##.#°C

MOIsT 1

nO

MOIsT 2

nO

OuT. TEMP

##.#°C

suPPlY w.

##.#°C

rETurn w.

##.#°C

alarM nO

shOw InfO

sETuP

rEsTarT

ExIT

dIsPlaY TExTs

ZOnE 1

Off

Heating zone 1 active (ON) or inactive (OFF)

ZOnE 2

Off

Heating zone 2 active (ON) or inactive (OFF)

sEnsOr 1

##.#°C

Sensor 1 (heated sensor) core temperature. Applies only when ETOG sensor is connected.

NOTE: The temperature shown does not equal ambient temperature during moisture detection!

sEnsOr 2

##.#°C

Sensor 2 (heated sensor) core temperature. Applies only when ETOG sensor is connected.

NOTE: The temperature shown does not equal ambient temperature during moisture detection!

MOIsT 1

nO

Sensor 1 moisture status. YES / NO / Blank. Blank will be shown if temperature is above Set Temp or the system

is in Afterrun mode.

MOIsT 2

nO

Sensor 2 moisture status. YES / NO / Blank. Blank will be shown if temperature is above Set Temp or the system

is in Afterrun mode.

OuT TEMP

##.#°C

Ambient outdoor temperature. Applies only when ETF sensor is connected.

suPPlY w.

##.#°C

Supply water temperature, hydronic application only.