SEt22

PROG

Setting Contents

Initial

Value

5

StRSt

Repeat Start Step Setting 3

1

Setting Value Range

1~Repeat End Step Setting

(ENdSt)

6

ENdSt

Repeat End Step Setting 3

StEPN

Repeat Start Step Setting (StRSt StRSt)~

Setting No. of Steps to be used or StEPN

※

When set to StEPN, the value which is set under the
Setting No. of Steps to be Used will be “Repeat End Step
Setting”.

7

RUNP

No. of Execution Setting / No. of Execution Monitor 3

1

Setting Value Range

RUNP=0~9999

(

When RUNP=0, Infinite)

Setting the condition of repeated operation during the programmed operation

*

5 Repeated Start Step Setting (StRSt)

This is to set the starting point of the repetition (Step No. of which the repetition starts)

*

6 Repeated End Step Setting (ENdSt)

This is to set the end point of the repetition (Step No. of which the repetition ends)

*

7 Setting No. of Executions / No. of Executions Monitor (RUNP)

This is to set the no. of time of repetition at the start point and end point.

NOTE: The setting value of the “No. of Executions Setting ” and “No. of Executions” done will be shown alternately only
on the display of the controller unit.

■

Repeat Operation Behavior Diagram

STEP1

STEP2

STEP3

STEP2

STEP3

STEP2

STEP3

STEP4

programmed

operation

start

Repeated Start Step Setting : STEP2
Repeated End Step Setting : STEP3
Setting No. of Executions  : 3 times

programmed

operation

end

Above is usage example of Repeat Operation Function