Display flashes

• You may be exceeding the 200psia and

550psia working ranges, or selected a
refrigerant unsuitable for the current pressure
reading.

• Disconnect pressure connection to system,

press ZERO to recalibrate

LCD has dim
contrast

• Press LCD ↑ to increase contrast
• Replace batteries with a fresh set

Display visibly
cracked

• Contact the manufacturer for service

Condensation
inside display
window

• Allow unit to warm to ambient temperature.
• Open battery compartment and allow unit to

dehumidify in a dry or air-conditioned
environment for 24 hours.

Keys do not
respond

• MIN/MAX CLR does not give visual results

when pressed in modes other than HI and LO,
but the pressure memory is cleared.

• Contact the manufacturer for service

Pressure port
loose against
case

• Tighten the speed nut using a deep socket or

wrench. Do not use excessive force. Apply
thread lock if desired

Mode changes
randomly
without MODE
key press

• When the temperature probe is installed, it

automatically enters t/sh/sc modes.

• When the temperature probe is removed, it

automatically enters normal mode.

• Check that the temperature probe is properly

installed, fully mated and locked on the plug.

Cannot access t,
SH or SC
modes

• Check that the temperature probe is properly

installed, fully mated and locked on the plug.
If either temperature sensor is defective, their
will be no t/sh/sc/dt showing up on the
display.