S

elector

aNd

d

iSplay

p

arameterS

o

N

ue

i

S

mart

B

ell

pluS

ZeRO” – Analyzer is performing the initial zero setting
CO (Carbon Monoxide) – Direct reading of the carbon dioxide sensor displayed

in parts per million (ppm)
CO2 (Carbon Dioxide) – Direct reading of the carbon monoxide sensor displayed

in percentage (%)

O2 (Oxygen) – O2 is calculated for each fuel type from the CO2 measurement. It

assumes that the combustion process is running fuel lean. It is important to make other

measurements to confirm that this assumption is always correct.
X-Air (Excess Air) – Excess Air is calculated for each fuel type from the CO2 measure-

ment. It assumes that the combustion process is running fuel lean. It is important to

make other measurements to confirm that this assumption is always correct.
TFlue (Flue Temperature) – TFlue is a direct measurement of the temperature at the tip

of the flue probe. This measurement is used to determine the net temperature for use in

calculation of combustion efficiency.
Eff (Efficiciency) – Calculated combustion (not appliance) efficiency based on measurements

of CO2, Flue Temperature and fuel selected. The SmartBell calculates gross combustion

efficiency and automatically determines if the combustion is in the condensing mode to make

appropriate corrections.
BAT symbol - Displays the Battery power available.
HIGH Displays at standby/power off if CO levels are greater than 20ppm.

NOTE: If turning unit off countdown will resume once CO levels are lesser

than 20ppm.

Fuels Available

GLOSSARY

11

Selector Position

Display

Type

L Oil

LOIL

Light Oil

Propane

PrOP

Propane

Nat Gas

n6AS

Natural Gas

H Oil

HOIL

Heavy Oil

Wood

vOOd

Wood