UEi Test Instruments SMART BELL PLUS KIT User Manual

Page 5

Advertising
background image

G

eNeral

m

aiNteNaNce

• Check calibration of your instrument annually to ensure it meets original performance specifications

• Keep your instrument dry. If it gets wet, wipe dry immediately. Liquids can degrade electronic circuits

• Whenever practical, keep the instrument away from dust and dirt that can cause premature wear

• Although your instrument is built to withstand the rigors of daily use, it can be damaged by severe

impacts. Use reasonable caution when using and storing the meter

p

eriodic

S

ervice

WARNING!

Repair and service of this instrument is to be performed by qualified personnel only. Improper repair or

service could result in physical degradation of the instrument. This could alter the protection from personal

injury this meter provides to the operator. Perform only those maintenance tasks that you are qualified to do.

a

NNual

r

e

-c

aliBratioN

While the sensors have an expected life of more than five years in normal use it is recommended that the

analyzer is re-calibrated annually. This is so that long-term drift can be eliminated. Local regulations may

require more frequent re-calibration and users should check with appropriate authorities to ensure compliance

with relevant guidelines.

c

leaNiNG

Periodically clean your instruments case using a damp cloth. DO NOT use abrasive, flammable liquids,

cleaning solvents, or strong detergents as they may damage the finish, impair safety, or affect the reliability

of the structural components.

e

mptyiNG

& c

leaNiNG

the

i

N

-l

iNe

w

ater

t

rap

The in-line water trap should be checked and emptied on a regular basis. Water vapor will condense in the

probe line, which may cause the water trap to fill suddenly if the probe is moved. Care should be taken

at all times.

Carefully un screw the plug from the bottom

of the water-trap housing. Dispose of the condensate in

a suitable drain, care must be taken as it could be acidic.

If condensate spills onto the skin or clothing, clean off

immediately using fresh water, seek medical advice

if problems occur. Ensure plug is replaced before

performing combustion tests. Note: CO2 reading will

be low if the Water Trap Plug is not in place.

c

haNGiNG

t

he

p

article

f

ilter

This is a very important part of the analyzer and should be changed regularly. It prevents dust and dirt

particles from entering the pump and sensors that will cause damage. The filter MUST be changed when

it appears discolored on the inner surface.

Remove water-trap assembly from the analyzer

as shown above. Remove the filter and plastic

holder from the housing. Discard the filter

element but keep the holder to fit to the new

filter. Clean the inside of the filter housing

with a suitable soft cloth. Fit the holder onto

the new filter element and then insert into the

housing. Refit the housing onto the analyzer.

Hook slides

out of dock

Slide outward

Unscrew plug

to drain

3

Insert a new filter

Advertising