LCD Display Functional Description

1. Primary Display: T1/T2 or T3/T4

2. TYPE KJET: Type of thermocouple.

3. SETUP: Setup is in progress.

4. RECALL: The logged readings are displayed.

5. OFFSET: The thermocouple measurement includes an offset.

6. HOLD: The display readings do not change.

7. LOW BATTERY: Replace batteries.

8. USB: The thermometer is connected to a PC via USB

interface port.

9. LOG: Readings are being logged.

10. ˚C,˚F, K: Temperature units.

11. Secondary Display: Internal temperature of the thermometer,

MEMORY, MIN, MAX, AVG, and T1-T2 or T3-T4.
reading. Shows the memory location initially when a logged
reading is recalled.

12. Time Display: 24-hour clock, shows the INTERVAL length in

SETUP. Shows elapsed time when AVG is on or before clock has
been set. Shows the memory time later on when a logged
reading is recalled.

3

1

2

3

4

5

6

7

8

9

10

11

12