Esc ixf1 retrieve fnc1 replacement setting, Esc ixf1, Retrieve fnc1 replacement setting – Brother QL-720NW User Manual
Page 87
Advertising

P-touch Template Command Reference
- 82 -
7. Control Command Details
ESC iXF1 Retrieve FNC1 replacement setting
ASCII: ESC
i
X
F
1
n1
n2
Decimal:
27 105
88 70 49 n1 n2
Hexadecimal:
1B 69 58 46 31 n1 n2
Parameters
n1: 00h (Fixed)
n2: 00h (Fixed)
Description
Retrieves the FNC1 replacement setting.
3-byte data is returned from the printer.
[1]: 01h
(Fixed)
[2]: 00h
(Fixed)
[3]: Setting
00h: FNC1 replacement setting OFF
01h: FNC1 replacement setting ON
The retrieved value is a value specified by a static command.
Example
When the FNC1 replacement setting is OFF:
Code: ESC i X F 1 00h 00h
(1Bh 69h 58h 46h 31h 00h 00h)
Returned value: 01h 00h 00h
Advertising