INSTALLATION

Check the appliance is electrically safe and gas sound when you have finished.

39

Stick on label

Stick the “NOW ADJUSTED FOR LP GAS” label next to the

ratings label inside the drawer cavity to indicate the gas the

appliance is now set for (Fig.8-12).

Pressure Testing

Connect the appliance to the gas supply. Check the appliance

is gas sound.
The gas pressure can be measured at the pressure test point

on the appliance side of the pressure regulator (Fig.8-13).
For proper operation, the pressure of LP supplied to the

regulator must be between 10’’ and 13’’ of water column

(2.49 - 3.24 kPa).
When checking for proper operation of the regulator, the

inlet pressure must be at least 1’’ (0.25 kPa) greater than the

operating (manifold) pressure as given above.
The pressure regulator located at the inlet of the range

manifold must remain in the supply line regardless of

whether natural or LP gas is being used.

ArtNo.102-0008 - Regulator cap

ArtNo.102-0010 - Adjusted to LP gas label

ArtNo.102-0009 - Gas regulator settings

Type 1

Type 2

Fig.8-10

Fig.8-11

Fig.8-12

ArtNo.102-0011 - Pressure test point

Fig.8-13