Warnings and cautions, Warnings, Cautions – American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOVRS User Manual

Page 4

Advertising
background image

SPEEDDOME ULTRA OUTDOOR HOUSING

8200-0492-02, REV. C

INSTALLATION GUIDE - CONTINUATION

4 of 12

Warnings and Cautions

Please review the following warnings and cautions
before you begin installation or service.

Warnings

WARNING!

Always use proper lift and

safety equipment for the location and
type of installation. Use the safety
features of the lift equipment.

WARNING!

When connecting wires,

ensure electrical power is not connected
to the camera dome. The dome will
move when power is applied. Also,
ensure electrical power is not connected
to nearby fixtures you might touch during
installation.

WARNING!

The camera dome runs on

24Vac. DO NOT connect line voltage to
the dome.

North America power requirements: In
North America, this device is intended to
be supplied from a Class 2 power
supply. For outdoor installations, use
Class 3 wiring techniques, liquid-tight
conduit, or liquid-tight pipe.
This installation should be made by a
qualified service person and should
conform to all local codes.

WARNING!

DO NOT install this housing

where combustible or explosive products
are stored or used.

WARNING!

EU power requirements:

This product runs on 24Vac. In the EU, it
is intended to be powered from a Limited
Power Source. A limited power source is
a certified source of SELV, and if
inherently limited, with 8 amps maximum
output current, and a maximum of 100VA
available; or if not inherently limited,
fused with a maximum value of 3.3
Amps, meeting section 2.11 of IEC950,
and a maximum of 250VA available. The
power supply can be obtained through
American Dynamics or through another
source where the provider can furnish
the required certification. This is required
to assure electrical safety in the product.

Cautions

Water leaks, even small ones, can
increase humidity inside the outdoor
housing. To help eliminate humidity,
follow all instructions explicitly and
also the following cautions:

- DO NOT use over seals such as

RTV and silicone caulks.

- Ensure blower/heater assembly

fans spin when power is on.

Also see “Preventing Condensation”
on page 5.

• To protect the bubble assembly, leave it in its

box until you are ready to install it.

• Do not run data/power cables adjacent to or in

the same conduit as line voltage mains power.

• Network cable/device requirements (additional

requirements are listed on page 6):

Network

Cable
Thickness
Required

Maximum
Devices per
Cable Run

SensorNet 0.326mm

2

(22AWG)

32

RS-422 0.326mm

2

(22AWG)

10

Manchester 0.823mm

2

(18AWG)

3

• Remove both slot covers from the eyeball to

prevent overheating

• Keep cables within the housing away from the

heater assembly

• If required, set data cable termination inside the

housing (see “Unterminating the Outdoor
Housing” on page 7).

• If possible, mount the housing so the least

needed view (such as a wall, building corner, or
pole) is opposite the blower/heater assembly.

• Protect this equipment from direct lightning

strikes. See Lightning Protection Reference
Guide
8200-0627-01 available online at
www.americandynamics.net.

!

!

!

!

!

Advertising