Connector pin assignments, Cable requirements, Data cable – American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOVRS User Manual

Page 6: Power cable

Advertising
background image

SPEEDDOME ULTRA OUTDOOR HOUSING

8200-0492-02, REV. C

INSTALLATION GUIDE - CONTINUATION

6 of 12

Connector Pin Assignments

GREEN CONNECTOR (POWER)

Pin Color Description

1 Black

24Vac

2 Red Common
3 White

24Vac

BLACK CONNECTOR (DATA)

Manchester

Pin Color*

Designation

1-4 —

Not

used.

5 White/Orange

Manchester

(White)

6 White/Yellow

Manchester

(Black)

RS-422 / SensorNet

Pin Color*

Designation

1

Orange

RS-422 Data In High (+)

2

Green

RS-422 Data In Low (–)

3

Yellow

RS-422 Data Out High (+)

4

Brown

RS-422 Data Out Low (–)

5 White/Orange

SensorNet

(unshielded)

6

White/Yellow

SensorNet (unshielded)

*Color based on composite cable.

GREEN CONNECTOR (TWISTED PAIR VIDEO)

Pin Color

Designation

1

+ (video high)

2

– (video ground)

GRAY CONNECTOR (RELAY ALARM OUTPUTS)

Pin Color Description

1 Blue Normally

Closed*

2 Purple

Common*

3 Gray Normally

Open*

4 Wht/Red

Alarm

Return

5

Wht/Blk

Alarm input 1 (3.5mA sink)

*Relay contact not to exceed 1A @ 30Vdc or

0.3A @ 125Vac.

BLUE CONNECTOR (ALARM INPUT)*

Pin Color

Designation

1

Wht/Blue

Alarm input 2

2

Wht/Brn

Alarm input 3

3

Wht/Purple Alarm input 4

4 Wht/Red

Alarm

Return

* 0101-0115-0X non-vandal resistant housing,

0101-0116-0X vandal-resistant housing.

Cable Requirements

Data Cable

The table below shows requirements for SensorNet,
RS-422, and Manchester networks. For more
information about communication protocols and
cable networks, see Communication Protocols and
Cable Networks, 8000-2573-19.

Data cable requirements

SensorNet

RS-422

Manchester

Cable type

1
unshielded,
twisted
pair*

2
shielded,
twisted
pair*

1
shielded
twisted
pair**

Wire gauge

22 AWG

22 AWG

18 AWG

Connection Non-

polarized

Polarized Polarized

Max.
devices on
line

32 10

3

* Power, data, and video cables can be ordered

separately or within a composite cable that can be
ordered in various lengths. Plenum-rated cables must
be used in indoor ceilings used for environmental air
return (called "other air space" in the National Electrical
Code). Order parts through your distribution network.

Note: If you order cable from an outside source, wire
colors may be different.

** Belden 88760 (plenum), or Belden 8760 cable (non-

plenum) cable is recommended. Plenum-rated cables
must be used in indoor ceilings used for environmental
air return (called "other air space" in the National
Electrical Code). Order

cable directly from Belden by

calling 1-800-235-3361.

Power Cable

The camera dome and housing are to be connected
to a Class 2 LPS, 24Vac, 80VA power source. Do
not exceed the maximum outdoor Class 2 ratings of
30Vac, 100VA.

0.823mm

2

(18AWG)

1.31mm

2

(16AWG)

2.08mm

2

(14AW)G

Low Line Voltage
102/204Vac

60m

(200ft)

100m

(320ft)

160m

(520ft)

Low Line Voltage
90/180Vac

30m

(100ft)

50m

(160ft)

80m

(260ft)

Advertising