Preventing condensation, Parts list for authorized users – American Dynamics SpeedDome Ultra Outdoor Housing ADSDUHOVRS User Manual

Page 5

Advertising
background image

SPEEDDOME ULTRA OUTDOOR HOUSING

8200-0492-02, REV. C

INSTALLATION GUIDE - CONTINUATION

5 of 12

Preventing Condensation

Damage, missing parts, or procedures
that most often allow water to enter
the housing are as follows (refer to
figures opposite):

†

Missing O-ring on cover, or missing sleeve or

seal on end cap assembly

†

Missing Teflon tape around any housing pipe

threads

†

RTV or similar sealant covering an air path

†

Blower fans not turning

†

Loose tamperproof screws in bubble assembly

†

Bent flange on metal housing that

compromises the gasket seal between the
bubble and the housing

†

Plugged drain holes in the bubble trim ring

†

Cracked

bubble

†

Tamperproof screws that are missing or

improperly tightened compromise the gasket
seal between the bubble and the housing

†

Ensure lanyard is not caught between: a)

flange and trim ring gasket, and b) trim ring
and sunshield

†

In high humidity environments, the desiccant

bag may need to be replaced occasionally.

Parts List for Authorized
Users

The parts listed below and shown in the exploded
view can only be ordered by authorized users. To
become authorized, contact your sales
representative.

1. Housing Assy., 0404-0260-03

2. Blower/Heater Assy., 0304-2906-01

3. I/O Board Assy., 0312-2124-03

4. Bubble Assy. (Clear), 0400-1402-01

5. Bubble Assy. (Smoke), 0400-1402-02

6. Drive, Tamperproof, 1400-0149-01

7. Screws, Tamperproof, 0500-8034-01 (x4)

8. Desiccant Kit, 0352-0207-02

Exploded view

Foam seal
(inside pipe)

Sleeve (outside),
Seal (inside end
cap assembly)

O-ring (inside

cover)

Bent flange

Gasket seal
between
bubble and
metal housing

Blower fans

1

2

3

6

4, 5

Additional shield (not
shown) used for vandal-
resistant version.

7

Advertising