Canon imagePROGRAF iPF8400S User Manual
Page 798

Note
•
Even if paper categorized as Unique calibration is used, if the media type has yet to execute color calibration even once
and does not have any dedicated calibration adjustment values, the calibration adjustment values are overwritten when
Common calibration is executed.
•
Calibration values configured by color calibration using the printer sensor and calibration values configured by color cali-
bration using the optional Spectrophotometer Unit are managed as separate data.
Because of this, the calibration values configured using the Spectrophotometer Unit are not overwritten when Common
calibration is executed using the printer sensor.
Checking the Applied Calibration Values
Depending on the paper type, it may be possible to execute color calibration using both the printer sensor and the
Spectrophotometer Unit and to have two sets of calibration values.
In this case, the calibration values that were set when color calibration was executed the last time are applied when
printing.
The currently applied calibration values can be checked using the Color Calibration Management Console or Control
Panel menu.
How to Check
How to Operate
Displayed Content
Check in the Col-
or Calibration
Management
Console.
Display the Paper Status dialog box and view
the Type.
(See "Calibration Sheet (Win-
dows).")
(See "Calibration Sheet (Mac
OS).")
•
Auto Adjust: Calibration values set using the printer sensor
•
Auto Adjust (High Precision): Calibration values set using the Spec-
trophotometer Unit
Check in the
menu of the Con-
trol Panel.
From Set./Adj. Menu, select Adjust Printer >
Calibration > Calibration Log and then view
Adjustment Type.
(See "Menu Settings.")
•
Common Calibration: Calibration values set using the printer sensor
(Common calibration)
•
Unique Calibration: Calibration values set using the printer sensor
(Unique calibration)
•
UniqCal HiPrec/Std: Calibration values set using the Spectrophotom-
eter Unit (Pattern Size is Standard)
•
UniqCal HiPrec/Lge: Calibration values set using the Spectrophotom-
eter Unit (Pattern Size is Large)
To Confirm the Paper Information Registered on the Printer
•
Refer to the Calibration sheet on the Color Calibration Management Console when checking details on the com-
puter.
(See "Calibration Sheet (Windows).")
(See "Calibration Sheet (Mac OS).")
•
To print media information, select Paper Details on the Control Panel menu.
The following is displayed in the Calibration field.
Display
Meaning
Standard
Supports color calibration using the printer sensor
High Precision
Supports color calibration using the Spectrophotometer Unit
OK(Common)
Executes Common calibration
OK(Unique)
Executes Unique calibration
N/A
Color calibration cannot be executed
N/A(Colorime-
try Only)
Color calibration cannot be executed, but it can be used for acquiring color
measurement data
Adjustment Types of Color Calibration
iPF8400S
Color Management
Color Calibration
798