Getting started, Grounding instructions, Liquefied petroleum (propane) gas conversion – Electrolux EW30GC60IS User Manual

Page 7: Warning, Caution

Advertising
background image

7

Getting Started

GRoundinG instRuctions

For personal safety, the cooktop must be properly grounded. For

maximum safety, the power cord must be plugged into an electrical

outlet that is correctly polarized and properly grounded.
DO NOT operate the cooktop using a 2-prong adapter or an extension

cord. If a 2-prong wall receptacle is the only available outlet, it is the

personal responsibility of the consumer to have it replaced with a

properly grounded 3-prong wall receptacle installed by a qualified

electrician.
See the

INSTALLATION INSTRUCTIONS packaged with this cooktop

for complete installation and grounding instructions.

liQuefied PetRoleuM (PRoPane) Gas conveRsion

This appliance can be used with Natural Gas and Propane Gas. It is shipped from the factory

for use with natural gas.
A kit for converting to LP gas is supplied with your cooktop. The kit is marked “FOR LP/

PROPANE GAS CONVERSION”. Follow the installation instructions which are inside the

envelope.
The conversion must be performed by a qualified service technician in accordance with the

kit instructions and all local codes and requirements. Failure to follow instructions could result

in serious injury or property damage. The qualified agency performing this work assumes

responsibility for the conversion.

WarNiNg

This appliance is equipped with a 3-prong grounding plug for your protection

against shock hazard and should be plugged directly into a properly grounded

receptacle. do not cut or remove the grounding prong from this plug.

Avoid fire hazard or electrical shock. do not use an adapter plug, an extension

cord, or remove grounding prong from electrical power cord. Failure to follow

this warning can cause serious injury, fire or death.

WarNiNg

Severe shock, or damage to the cooktop may occur if the cooktop is not installed by a qualified installer or

electrician.

CautioN

Any additions, changes or conversions required in order for this appliance to satisfactorily meet the application

needs must be made by a qualified service technician in accordance with the manufacturer’s instructions and

all codes and requirements of the authority having jurisdiction. Failure to follow the instructions could result in

serious injury or property damage. The qualified agency performing this work assumes responsibility for the

conversion.

Power supply cord with

3-prong grounding plug

Grounding

type wall

receptacle

do not, under any

circumstances, cut,

remove, or bypass the

grounding prong.

Advertising