Disconnect the appliance from the

electrical supply, before you do
maintenance work or cleaning.

WARNING!
Risk of injury from electrical cur-
rent. Carefully obey the instruc-
tions for electrical connections.

• The electrical mains terminal is live.
• Make the electrical mains terminal free

of voltage.

• Install correctly to give anti-shock pro-

tection.

• Loose and incorrect mains plug and

socket connections can make the ter-
minal become too hot.

• A qualified electrician must install the

clamping connections correctly.

• Use a strain relief clamp on cable.
• Use the correct mains connection cable

and replace the damaged mains cable
with the proper cable type. Speak to
your local Service Centre.

The appliance must have the electrical in-
stallation which lets you disconnect the
appliance from the mains at all poles with
a contact opening width of minimum 3
mm. You must have correct isolation devi-
ces: line protecting cut-outs, fuses (screw
type fuses removed from the holder),
ground leakage trips and contactors.
The manufacturer is not responsible
for any injury to persons and pets or
damage to property caused by failure
to obey these requirements.

8.2 Electrical connection

• Do not pull the mains cable to discon-

nect the appliance. Always pull the
mains plug (if applicable).

• The appliance must not be connected

with an extension cable, an adapter or
a multiple socket. There is a risk of fire.

• Do not let the power cable to heat up

to a temperature of more than 90° C.
The cable should be guided by means
of clamps fixed to the side of the cabi-
net, in order to avoid any contact with
the equipment beneath the cooktop.

• Make sure that there is access to the

mains plug after the installation.

Electrical Requirements

Permanent electrical installation must
agree with the latest I.E.E. Regulations
and local Electricity Board regulations. For
your own safety the installation must be
done by a qualified electrician (e.g. your
local Electricity Board, or a contractor
who is on the roll of the National Inspec-
tion Council for Electrical Installation Con-
tracting [NICEIC]).

The manufacturer refuses to be
held responsible, if these safety
measures are not abided by.

Supply connections:
This hob has to be connected to 230 —
240 V ( 50 Hz) electricity supply.
Before carrying out the connection, make
sure:

1.

The limiter valve and the electrical
system can take the appliance load
(see the rating plate)

2.

The supply system is equipped with
an efficient earth connection in com-
pliance with the current standards
and regulations

3.

The outlet or omnipolar switch used
for connection is easily accessible
with the appliance installed.

The appliance is supplied with a 3 core
flexible power cable requiring a 13 amp
plug fitted with a 13 amp or 3 amp fuse
dependent on the load. You must pur-
chase and install the plug.
The wires in the cord are coloured as fol-
lows:

Green and yellow

- Earth

Blue

- Neutral

Brown

- Live

Replacement of the connection cable

1.

Connect the green and yellow (earth)
wire to the terminal which is marked
with the letter 'E', or the earth symbol

, or coloured green and yellow.

2.

Connect the blue (neutral) wire to the
terminal which is marked with the let-
ter 'N' or coloured blue.

3.

Connect the brown (live) wire to the
terminal which is marked with the let-
ter 'L' and is always connected to the
network phase.

ENGLISH