3 building in – Electrolux EHF3920BOK User Manual

Page 22

Advertising
background image

There must be no cut or stray strands of
wire present. The cord clamp must be
correctly attached to the outer sheath.

To replace the connection cable
use only H05V2V2-F T90 or
equivalent type. Make sure that
the cable section is applicable to
the voltage load and the working
temperature. The yellow/green
earth wire (B) must be approxi-
mately 2 cm longer than the live
and neutral wire (A).

A

B

WARNING!
A cut off plug inserted into a 13
amp socket is a serious safety
(shock) hazard. Ensure that the
cut off plug is disposed of safely.

The replacement of electric cable
must be carried out exclusively by
the service force centre or by per-
sonnel with similar competencies,
in accordance with the current
regulations.

8.3 Building in

40-50 mm

55 mm

30 mm

min. 650 mm

490 mm

270 mm

If several 30 cm hobs are to be installed
side by side into the same cut out, an as-
sembly kit including a support side brack-
et and supplementary seals is available at
our Service Centres. The relevant installa-
tion instructions are supplied within the kit
package.

490

+1

mm

270

+1

mm

R 5mm

55mm

8.4 Possibilities for insertion

Kitchen unit with door

The panel installed below the hob must
be easy to remove and let an easy access
in case a technical assistance intervention
is necessary.

min 20 mm

(max 150 mm)

30 mm

60 mm

B

A

A)

Removable panel

B)

Space for connections

22 www.electrolux.com