Electrolux EFA90600X User Manual

Page 17

Advertising
background image

17

Speed timer button
This function allows to time the extracting speed (power) selected and can
be activated by pressing key 2 for about 3 seconds, after the time has
elapsed the hood switches off.
The timer functions in the following way:

Speed 1 - 20 minutes (the number "1" and a small flashing LED light
appear on the display)

Speed 2 - 15 minutes (the number "2" and a small flashing LED light
appear on the display)

Speed 3 - 10 minutes (the number "3" and a small flashing LED light
appear on the display)

High-speed - 5 minutes (the number "4" and a small flashing LED light
appear on the display)

To quit the timed mode press key 1 to switch off the hood in advance; press
key 2 to get back to the previous speed and setting, press key 4 to activate
the Sensor mode.

Grease filter indicator
After 80 hours of operation, the number "1" starts flashing on the display.
Press and hold button 1 or 3 to reset the indicator.
Carry out maintenance on the grease filter according to the indications of this
manual.

Charcoal filter indicator
After 320 hours of operation, the number "2" starts flashing on the display.
Press and hold button 1 or 3 to reset the indicator.
Carry out maintenance on the charcoal filter according to the indications of
this manual.
When both filter signals appear simultaneously, numbers "1" and "2" will
alternately flash on the display.
Reset the indicator by performing the above-mentioned procedure twice.
The first operation resets the grease filter indicator, while the second
operation resets the charcoal filter indicator.
The charcoal filter indicator is not active in the standard mode.
If the hood is used in the recirculation mode, the charcoal filter indicator must
be activated.

Perform the following steps to activate the charcoal filter indicator:
Turn the hood off and keep buttons 2 and 3 pressed for 3".
The numbers "1" and "2" will flash for 2" once the function has been
activated.
Charcoal filter indicator deactivation:
Turn the hood off and keep buttons 1 and 2 pressed for 3".
The number "1" will flash for 2" to indicate that the function has been
deactivated.

Automatic functioning:
The hood is set to the traditional functioning mode, to activate the automatic
functioning press key 4.
The automatic functioning has two different modes.
COOKING mode, which guarantees proper extraction during cooking.
AIR QUALITY CONTROL mode, which guarantees high quality air level.
The two modes can be activated cyclically by pressing key 4.
COOKING mode, the display shows letter "C":
During cooking the system reacts promptly to increases in Vapour/Gas and
runs at the established speed for at least 1 minute, before getting back to the
lowest speed/switching off.
When cooking is finished and the level of the room parameters is as before
cooking, the system switches off.
If the parameters are close to the rest condition, the system forces the hood
to switch off after 30 minutes.
AIR QUALITY CONTROL mode, the display shows letter "A":
The system reacts promptly to increases in Vapour/Gas and runs at the
established speed for at least 1 minute, before getting back to the lowest
speed/switching off.
When the effect of the Vapours/Gases is finished and the level of the room
parameters is as before starting, the system switches off.
To quit this mode press keys 1, 2 and 4.
Sensor test
It takes place constantly during the automatic functioning. In the case of
failure, the display shows number "8" flashing (contact the technical
service), the hood can be used in manual mode anyway.

Manual calibration
Set the hood to OFF and keep keys 1 and 4 pressed contemporaneously for
3”.
A dot flashes on the display.
This operation is recommended:
when installing the hood for the first time
when cutting off electricity for many hours or days
when a very quick temperature variation occurs in the kitchen
Hob selection
This operation optimizes the automatic functioning of the hood, proceed as
follows:
Set the hood to OFF
Keep keys 1 and 3 pressed contemporaneously for 3” until the hob being
used is displayed.
"g" on: Gas Hob
"i" on: Induction Hob
"e" on: Electric Hob
To select the hob cyclically press key 1
The acceptance of the selected hob is displayed by the sequence of 3
flashes of the letter related to the selected hob.
Once the hob has been selected, to accept the function, wait for 10”.
The default hob is the Gas Hob.

Maintenance
ATTENTION!
Before performing any maintenance operation, isolate the
hood from the electrical supply by switching off at the connector and
removing the connector fuse.
Or if the appliance has been connected through a plug and socket, then the
plug must be removed from the socket.
The cooker hood should be cleaned regularly (at least with the same
frequency with which you carry out maintenance of the fat filters) internally
and externally. Clean using the cloth dampened with neutral liquid
detergent. Do not use abrasive products. DO NOT USE ALCOHOL!
WARNING: Failure to carry out the basic cleaning recommendations of the
cooker hood and replacement of the filters may cause fire risks.
Therefore, we recommend observing these instructions.
The manufacturer declines all responsibility for any damage to the motor or
any fire damage linked to inappropriate maintenance or failure to observe
the above safety recommendations.

Grease filter
Fig. 25-30
The grease filter
must be cleaned once a month using non aggressive
detergents, either by hand or in the dishwasher, which must be set to a low
temperature and a short cycle. When washed in a dishwasher, the grease
filter may discolour slightly, but this does not affect its filtering capacity.

Charcoal filter (filter version only)
Fig. 27
The saturation of the charcoal filter occurs after more or less prolonged use,
depending on the type of cooking and the regularity of cleaning of the grease
filter.
In any case it is necessary to replace the cartridge at least every four
mounths (or when the filter saturation indication system – if envisaged on the
model in possession – indicates this necessity).The charcoal filter may NOT
be washed or regenerated.


Replacing lamps
Fig. 31
Disconnect the hood from the electricity.
Warning! Prior to touching the light bulbs ensure they are cooled down.
Replace with a new 12 Volt, 20 Watt (Maximum) halogen light made for a G-
4 base SUITABLE FOR USE IN OPEN LUMINAIRES. Follow package
directions and do not touch new light with bare hands.

Advertising