Press any A-16R button to acknowledge the transfer status message

and return the A-16R to normal operation.

Loading an All Preset File via MIDI

As when loading a single Preset via SysEx, to load an All Preset data

file the A-16R must first be placed into MIDI Recall Mode.

The A-16R will remain in MIDI Recall until a valid A-16R MIDI

message is received, or until another front panel button is pressed to

exit MIDI mode. MIDI SysEx information for other manufacturer’s

devices will pass through the A-16R and be ignored.

To load an All Preset data file via SysEx:

1. Set the A-16R front panel

R

EMOTE

/L

OCAL

switch to the

L

OCAL

position.

2. Press the

R

ECALL

button. The R

ECALL

button LED

flashes.

3. Press the

S

OLO

button to arm the A-16R for MIDI

reception. The LED in the

S

OLO

button will blink.

4. Send the All Preset SysEx data file from your MIDI

storage device.

5. The sixteen Presets are loaded into the A-16R internal

memory sequentially.

6. The Mute LEDs will serve as a progress bar. The

LEDs will light in order from 1 to 16 as each Preset is

received successfully.

When the All Preset SysEx file transfer is complete, the system

will display a status message to confirm that the data was received

properly. Two messages are possible:

• Valid Data Received - all yellow Mute LEDs will flash
• Invalid Data or MIDI Error - all red Channel LEDs will

flash

Press any A-16R button to acknowledge the transfer status message

and return the A-16R to normal operation.

Exit MIDI Mode

You can exit an All Preset SysEx load operation by pressing any A-16R

front panel button, or by changing the position of the Remote/Local

switch. Presets that have been successfully received prior to exiting

the SysEx recall mode will be preserved in the internal memory of