Installation

Installation

Remove packing materials from the wall sleeve and tape
from the air conditioner.

INSTALLATION REQUIREMENTS

If you use an existing wall sleeve, you should
measure its dimensions.
Install the new air conditioner according to these
installation instructions to achieve the best
performance. All wall sleeves used to mount the new
air conditioner must be in good structural condition
and have a rear grille to securely attach the new air
conditioner. (Figure 1)

With the LGE sleeve(optionally supplied with

your unit), you can maintain the best performance of
the new air conditioner. (Figure 2)

ELECTRICAL SERVICE

Check your available electrical service. The power
supply available must be the same as that shown on
the unit nameplate (found on left side of cabinet).

All models are equipped with a 3-prong service plug
to provide proper service and safe positive
grounding. Do not change plug in any way. Do not
use an adapter plug. If your present wall outlet does
not match your plug, call a qualified electrician to
make the necessary corrections. SAVE CARTON for
storage and this OWNER'S MANUAL for future
reference. The carton is the best way to store unit
during winter or when not in use.

INSTALLATION HARDWARE

14-

13

/

32

"

(366 mm)

24"(610 mm)

18-

15

/

32

"(468 mm)

20-

3

/

32

"

(511 mm)

1

5

6

7

8

3

2

4

9

2 Size options

2 Size options

To avoid risk of personal injury, property

damage, or product damage due to the weight of

this device and sharp edges that may be

exposed:

• Air conditioners covered in this manual pose an

excessive weight hazard. Two or more people are

needed to move and install the unit.

To prevent injury or strain, use proper lifting and

carrying techniques when moving unit.

• Carefully inspect location where air conditioner will

be installed. Be sure it will support the weight of

the unit over an extended period of time.

• Handle air conditioner with care. Wear protective

gloves whenever lifting or carrying the unit. AVOID

the sharp metal fins of front and rear coils.

• Make sure air conditioner does not fall during

installation.

REQUIRED TOOLS:
• Tight Fitting gloves
• Standard screwdriver
• Phillips screwdriver
• Pliers
• Sharp knife

• 3/8-inch open end

wrench or adjustable

wrench

• 1/4-inch hex socket

and ratchet

• Tape measure
• Electric drill
• 1/4-inch drill bit

Figure 1

Air Conditioner

ITEM

NAME OF PARTS

Q'TY

1

PLASTIC GRILLE

1

2

VERTICAL INSULATION STRIP

1

3

AROUND INSULATION STRIPS

2

4

HORIZONTAL INSULATION STRIP

1

5

SUPPORT BLOCK

2

6

BAFFLE

1

7

TRIM FRAME

2

8

SHIM

2

9

PLASTIC NUTS AND WASHER SCREWS

4

15-

17

/

32

"

(394 mm)

16-

23

/

32

"

(425 mm)

25-

7

/

8

"

(656 mm)

Aluminum metal grille