Filter, Warning, Caution – LG LSC27935SB User Manual

Page 21

Advertising
background image

20

FILTER

Performance Data Sheet

Models Number 5231JA2006E

Use with replacement cartridge 5231JA2006E

This system has been tested according to NSF/ANSI Standards 42 for the reduction of the substances listed below.

The concentration of the indicated substances in water entering the system was reduced to a concentration less than

or equal to the permissible limit for water leaving the system as specified in NSF/ANSI 42.

System tested and certified by NSF International against NSF/ANSI Standard 42 for the reduction

of Chlorine Taste and Odor and Nominal Particulate Class III.

Contaminant

Reduction

Average

Influent

Influent Challenge

Concentration.

Units apply to

each row

Product

Water

Average

%

Reduction

NSF

Reduction

Requirements

Max

Effluent

mg/L

Min %

Reduction

NSF Test

Nominal Particulate
Class I Particle size:
›0.5 to ‹1 um

5600000

At least 10,000

particles/ml

915

96

≥ 85%

470000

91.6%

511032-03

Chlorine taste and
odor

1,9 mg/L

2,0 mg/L ± 10%

0,07

96,4

≥ 50%

0.05 mg/L

97.4%

511032-03

* To a capacity of 300 gallons (1.135 L).

* Note that while the testing was performed under standard laboratory conditions, actual performance may vary.

Application Guidelines / Water Supply Parameters

Water Pressure

20 - 120 psi (138 - 827 kPa)

Water Temperature 33 ºF - 100 ºF (0,6 ºC - 38 ºC)
Service Flow

0,5 gpm (1,9 lpm)

WARNING

To reduce the risk associated with ingestion of

contaminants due to use with water that is micro

biologically unsafe or of unknown quality. Do not

use with water that is micro biologically unsafe or of

unknown quality without adequate disinfection before

or after the system.

Systems must be installed and operated in accordance

with manufacturer’s recommended procedures and

guidelines.

CAUTION

To reduce the risk of property damage due to water

leakage:

• Read and follow Use instructions before installation

and use of this system.

• Install on COLD water lines only. Comply with all

state and local plumbing codes.

• Company with all state and local plumbing codes.

Never install or operate where inlet water pressure

may exceed 125 psi (862 kPa).

• Protect filter from freezing. Remove filter in

temperatures below 34 °F (1 °C).

• Replace cartridge at specified service interval.

Cartridge MUST be replaced at least every 6 months.

• After replacing the water filter cartridge, dispense

2,5 gallons (9,46 liters) of water to purge the system,

depressing and releasing the dispenser pad in cycles

of 30 seconds ON and 60 seconds OFF. Discard

the purged water.

To purchase or replace water filters call your Service

Center. Refer to the Warranty Card to obtain the

telephone number of the Service Center near you and

ask for part no. 5231JA2006E.

*