vENTING THE DRYER

Do not crush or collapse ductwork. Failure

to follow these instructions can result in fi re

or death.

Do not allow ductwork to rest on or

contact sharp objects. Failure to follow these

instructions can result in fi re or death.

If connecting to existing ductwork, make

sure it is suitable and clean before installing

the dryer. Failure to follow these instructions

can result in fi re or death.

Venting must conform to local building

codes. Failure to follow these instructions can

result in fi re or death.

GasdryersMUSTexhausttotheoutdoors.

Failure to follow these instructions can result

in fi re or death.

Use only 4 in. (10 cm) rigid or fl exible metal

ductwork inside the dryer cabinet and

for venting outside. Failure to follow these

instructions can result in fi re or death.

To reduce the risk of fi re, combustion, or

accumulation of combustible gases, DO

NOT exhaust dryer air into an enclosed and

unventilated area, such as an attic, wall,

ceiling, crawl space, chimney, gas vent, or

concealed space of a building. Failure to

follow these instructions can result in fi re

or death.

To reduce the risk of fi re, DO NOT exhaust

the dryer with plastic or thin foil ducting.

Failure to follow these instructions can result

in fi re or death.

The exhaust duct must be 4 in. (10 cm) in

diameter with no obstructions. The exhaust

duct should be kept as short as possible.

Make sure to clean any old ducts before

installing your new dryer. Failure to follow

these instructions can result in fi re or death.

Rigid or semirigid metal ducting is

recommended for use between the dryer

and the wall. In special installations when

it is impossible to make a connection with

the above recommendations, a UL-listed

fl exible metal transition duct may be used

between the dryer and wall connection only.

The use of this ducting will affect drying

time. Failure to follow these instructions can

result in fi re or death.

DO NOT use sheet metal screws or other

fasteners which extend into the duct that

could catch lint and reduce the effi ciency

oftheexhaustsystem.Securealljoints

with duct tape. Failure to follow these

instructions can result in fi re or death.

To maximize operating results, please

observe the duct length limitations noted in

the chart on page 15. Failure to follow these

instructions can result in fi re or death.

Ductwork is not provided with the dryer.

You should obtain the necessary ductwork

locally. The end cap should have hinged

dampers to prevent backdraft when the

dryer is not in use. Failure to follow these

instructions can result in fi re or death.

The Total length of fl exible metal duct shall

not exceed 8 ft.(2.4m)

In Canada, that only those foil-type fl exible

ducts, if any, specifi cally identifi ed for use

with the appliance by the manufacturer

shall be used. In the United States, that only

those foil-type fl exible ducts, if any, specifi cally

identifi ed for use with the appliance by the

manufacturer and that comply with the Outline

for Clothes Dryer Transition Duct, Subject

2158A, shall be used.

w

WARNING:

To reduce the risk of fire, electric shock, or injury to persons when using this

appliance, follow basic precautions, including the following: