24 in.

2*

(155 cm

2

)

1"*

(2.5 cm)

5"**

(12.7 cm)

48 in.

2*

(310 cm

2

)

14" max.*

(35.6 cm)

3"

*

(7.6 cm)

3"

*

(7.6 cm)

1"

(2.5 cm)

27"

(68.6 cm)

1"

(2.5 cm)

1"*

(2.5 cm)

5"**

(12.7 cm)

14" max.*

(35.6 cm)

18" min.*

(45.7 cm)

0"

(0 cm)

39" min.

(98.3 cm)

1"

(2.5 cm)

27"

(68.6 cm)

1"

(2.5 cm)

Closet Door Vent

Requirements

18" min.*

(45.7 cm)

30"

(76.1cm)

30"

(76.1cm)

IMPORTANT: Read all installation instructions completely before

installing and operating your dryer!

It is important that you review this entire manual before installing and using your dryer. Detailed instructions

concerning electrical connections, gas connections, and exhaust requirements are provided on the

following pages.

CLEARANCES

Do not operate your dryer at temperatures below 45 ºF (7 ºC). At lower temperatures, the dryer might not shut off at the

end of an automatic cycle. This can result in longer drying times.

The dryer must not be installed or stored in an area where it will be exposed to water and/or weather.

Check code requirements. Some codes limit, or do not permit, installation of the dryer in garages, closets, mobile

homes or sleeping quarters. Contact your local building inspector.

NOTE: No other fuel-burning appliance can be installed in the same closet as a dryer.

INSTALLATION LOCATION REQUIREMENTS

A location that allows for proper exhaust installation.

A gas dryer must be exhausted to the outdoors. See

Venting Requirements.

A grounded electrical outlet located within 2 ft.

(61 cm) of either side of the dryer. See

Electrical

Requirements.

A sturdy floor to support the total dryer weight of

200 lbs (90.7 kg). The combined weight of a companion

appliance should also be considered.

A level floor with a maximum slope of 1 inch (2.5 cm)

under entire dryer. If slope is greater than 1 inch (2.5

cm), install Extended Dryer Feet Kit. Clothes may not

tumble properly, and automatic sensor cycles may not

operate correctly if dryer is not level.

For a garage installation, you will need to place the dryer

at least 18 inches (46 cm) above the floor. If using a

pedestal, you will need 18 inches (46 cm) to the bottom

of the dryer.

The following spacing dimensions are recommended

for this dryer. This dryer has been tested for spacing

of 0 inches (0 cm) clearance on the sides and rear.

Recommended spacing should be considered for the

following reasons:

Additional spacing should be considered for ease of

installation and servicing.

Additional clearances might be required for wall, door

and floor moldings.

Additional spacing should be considered on all sides of

the dryer to reduce noise transfer.

For closet installation, with a door, minimum ventilation

openings in the top and bottom of the door are required.

Louvered doors with equivalent ventilation openings are

acceptable.

Companion appliance spacing should also be

considered.

Suggestion: There should be at least a little space around the dryer (or any other appliance) to eliminate the transfer

of vibration from one to the other. Too much vibration, it could cause them to make noise or touch each other causing

paint damage and making even more noise.

Installation spacing for recessed area or closet installation