Installation, Drain connection – Alliance Laundry Systems BF50PV User Manual

Page 25

Advertising
background image

23

Installation

F232058

Drain Connection

A drain system of adequate capacity is
essential to washer-extractor performance.
Ideally, the water should empty through a
vented pipe directly into a sump or floor drain.
Figures 13 and 14 show drain line and drain
trough configurations.

Figure 13

A flexible connection must be made to a
vented drain system to prevent an air lock and
to prevent siphoning. If proper drain size is not
available or practical, a surge tank is required.
A surge tank in conjunction with a sump pump
should be used when gravity drainage is not
possible, such as in below-ground-level
installations.

Before any deviation from specified
installation procedures is attempted,
the customer or installer should contact
the distributor.

Increasing the drain hose length, installing
elbows, or causing bends will decrease drain
flow rate and increase drain times, impairing
washer-extractor performance.

Figure 14

See the Cabinet Freestanding Drain
Information table in this subsection for
capacity-specific drain information.

Installation of additional washer-extractors
will require proportionately larger drain
connections. See the Cabinet Freestanding
Drain Line Sizing table in this subsection.

Waste Line

Rear of Machine

Vent

Drain Pipe

Tee

Waste Line

P024I1A

Rear of Machine

Drain Pipe

Steel Grate

Drain

Trough

Strainer

Line

Waste

P025I1A

Advertising
This manual is related to the following products: