Installation – Alliance Laundry Systems BF50PV User Manual

Page 42

Advertising
background image

Installation

40

F232058

Note:

Ensure cables are routed safely and

away from potential hazards. Use wire ties,
included with the kit, to secure cabling.
Provide some slack for repositioning of the
canister/filter/pump assembly after electrical
connections are made.

d. One the 35- and 50-pound models,

route the 2-conductor and 4-conductor
cable through the two PG 13.5 strain
reliefs installed in step b. See Figure 23.
On the 85-pound model, route both the
2-conductor cable and the 4-conductor
cable through the PG 21 strain relief as
shown in Figure 24.

Note:

Ensure strain reliefs are tightened

securely around the cable.

e. Connect red wire in the 2-conductor

cable from the canister/filter/pump
assembly to terminal A2 of the pump
contactor. See Figure 23.

f. Extend 2-conductor cable #223, which

is capped in the rear control module.
Connect red wire of #223 to the black
wire of the 2-conductor cable from the
canister/filter/pump assembly.

g. Connect the black wire of the #223

cable to terminal A1 of the pump
contactor.

h. Connect L1, L2, and L3 from the circuit

breaker to the input side of the mains
contactor, using the 18GA gray wire,
included in the kit.

i. Connect the 4-conductor cable wires to

the pump contactor terminals as
follows: wire No. 1 to terminal T1, wire
No. 2 to T2, and wire No. 3 to T3. Wire
No. 4 (green-yellow) must be
connected to the chassis ground.

Note:

If pump motor rotation is incorrect

during the control function test, swap any two
wires at terminals T1, T2, or T3 of pump
contactor. See Figure 26 for correct motor
rotation direction.

7. Verifying electrical connections:

a. Secure any loose or dangling wires,

using the wire ties.

b. Verify that all connections are secure

and routed properly.

8. Reassembling machine panels:

a. Reassemble rear panel and right front

panel.

b. Reinstall rear control module cover.

9. Install water recirculation piping:

a. Remove the cap on the recirculation

inlet on top of the shell. See
Figure 20.

b. Attach the 1 1/2-inch black hose

connector (no clamp grooves), included
in the kit, between the shell
recirculation inlet and the adapter plate.

c. Attach upper recirculation pipe to the

hose connector at the recirculation
adapter plate on the rear of the washer-
extractor. See Figure 26.