background image

Installation

44

F232058

Wet Clean Processing

For wet clean processing, program the
standard test cycle to verify proper operation
of the wet clean system. (Refer to the Cabinet
Freestanding Operation/Programming
manual.)

Run the test cycle and verify that the wet clean
system is operating properly:

Check plumbing connections for leaks.

Verify that the Premium Wet Clean

Module pump is operating properly, and
that the rotation direction is
counterclockwise. If rotation direction is
incorrect, a qualified electrician may
reverse any two leads. See Step 6i of
Premium Wet Clean Module installation
section.

Verify that the drain valve on the Premium

Wet Clean Module opens and closes
properly.

Verify that the canister lid does not leak.

If problems arise during the control function
test, stop the washer-extractor and return to the
Premium Wet Clean Module installation
section for proper installation of components
and wiring.

Advertising
This manual is related to the following products: