SmartJack Loopback Commands

The HiGain HDSL2 SmartJack (SMJK) Loopback (LPBK) commands allow you to use in-band, out-of-band, and
universal codes to initiate and terminate loopback testing of the HiGain HDSL2 circuit. (See

“SmartJack Test

Procedure” on page 64

for additional information.)

M

ANUAL

L

OOPBACK

S

ESSION

A manual loopback session allows you to select any one of the HiGain HDSL2 loopbacks listed in

Table 22 on

page 56

.

Setting the Loopback Time-Out Option

Before initiating a loopback session, verify that the Loopback/MTA Time-out parameter is set to the desired
setting.

1

Use the MODE and LBK pushbuttons as described in

“Setting Options through MODE and LBK” on page 10

.

The Loopback Time-out parameter is also user-selectable from the System Settings screen when using a
maintenance terminal.

2

Select the desired setting:

•

NONE (time-out disabled)

•

20 minutes

•

60 minutes

•

120 minutes (default setting)

Activating Manual Loopback Mode

To initiate a manual loopback session:

1

Press both the MODE and LBK pushbuttons on the front panel for at least 3 seconds. The following message
appears on the front-panel display:

MAN LPBK NLO?

With the exception of SmartJack, any of the HiGain HDSL2 loopbacks can be executed using the
MODE and LBK pushbuttons.

When executing a manual loopback session using the MODE and LBK pushbuttons:

•

The next loopback option can be displayed by pressing the MODE pushbutton, however, the
previously activated loopback remains active until the LBK pushbutton is pressed, which
activates the new loopback.

•

If neither pushbutton is pressed for a period of 30 seconds and no loopback is in effect, the
manual loopback session terminates and the display returns to normal mode.

•

If any loopback is in effect, the 30-second time-out is inhibited. The active loopback and the
manual loopback session continue until the loopback times out in accordance with the LBTO
setting.

•

Only the SMJK loopback can exist with other network loopbacks at any given time.

•

If there is an active loopback, pressing the MODE and LBK pushbuttons for 3 or more
seconds terminates any active loopback, ends the manual loopback session and returns the
display to normal mode.