Testing

H2TU-C-319 List 4E

January 9, 2002

63

5

Once the test is complete, do one of the following:

•

If the system is to loopdown but remain Armed, send the IR (Intelligent Repeater) LPDN code for
universal loopdown.

•

If all the equipment is to be looped down, disarmed and returned to normal operation, send the disarm
in-band code 11100 or the ESF DL code (FF24).

The Time-out Override function is only valid for the current active loopback. The automatic
time-out timer is restored during subsequent loopback sessions.

The Armed mode has an automatic time-out of 120 minutes, but this timer is reset to 120 for any
of the following events:

•

Loopback terminates (manually or time-out)

•

Query

•

Alternate query

•

Far-End activate

•

Another ARM command

This timer is inhibited while any of the valid command codes are being sent. Once the codes
are removed, the timer restarts at 120.