Avocent Advanced Console Server ACS 6000 User Manual

Page 34

Advertising
background image

24 Cyclades ACS 6000 Advanced Console Server Command Reference Guide

8.

Enter

set port_settings/serial_profile=cas

then enter

commit

as shown to assign the CAS

profile and save the settings.

--:- port_settings cli-> set port_settings/ serial_profile=cas

**:- port_settings cli-> commit

--:- port_settings cli->

9.

Enter

set port_settings/status=enabled

, then enter

commit

and

show

as shown to enable the

configured port, save the settings and verify the configuration.

--:- port_settings cli-> set port_settings/ status=enabled

**:- port_settings cli-> commit

--:- port_settings cli-> show

To enable a power management port:

1.

Log onto the CLI as an administrator and enter

cd appliance_settings/ports/physical_ports/

<port_name>

to select a port with a PDU connected (port 3 is used as an example).

--:- Units cli-> cd appliance_settings/ports/physical_ports/

serial_ports/3

2.

Enter

show

to view the configuration of port 3.

--:- 3 cli-> show

3

port_settings/

--:-3 cli->

3.

Enter

cd port_settings

to configure port 3.

--:- 3 cli-> cd port_settings

4.

Type

set

then press

Tab Tab

to view the configuration options.

--:- port_settings cli-> set <

Tab

><

Tab

>

communication_settings port_settings

5.

Enter

show

to view the configuration of port 3.

--:-port_settings cli-> show

port_settings

port: 3

status = disabled

rj45_pin-out = cyclades

serial_profile = unconfigured

communication_settings

speed = 9600

parity = None

data_bits = 8

stop_bits = 1

flow_control = none

Advertising